2019
DOI: 10.1109/tia.2019.2932966
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Series and Parallel Hybrid Filters Applied to Hot Strip Mills With Cycloconverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(13 citation statements)
references
References 12 publications
0
13
0
Order By: Relevance
“…where 𝑉 𝑛 is the unbalanced voltage on the phases of active filter acquired from grid phase imbalance. On the other hand, the unbalanced voltage can be computed from the zero-sequence voltage of the line in (2). Parallel structured inverters and the SAPF filter coupling with the grid have similar characteristics, which are all affected by the condition of resonance and have remained the focus of research [6,[22][23][24].…”
Section: Sapf Designmentioning
confidence: 99%
See 1 more Smart Citation
“…where 𝑉 𝑛 is the unbalanced voltage on the phases of active filter acquired from grid phase imbalance. On the other hand, the unbalanced voltage can be computed from the zero-sequence voltage of the line in (2). Parallel structured inverters and the SAPF filter coupling with the grid have similar characteristics, which are all affected by the condition of resonance and have remained the focus of research [6,[22][23][24].…”
Section: Sapf Designmentioning
confidence: 99%
“…As a solution to this problem, passive filters were commonly used for harmonic suppression in earlier times. However, as these filters have a high switching resonance effect [2][3][4][5], the idea of using active filters has been given greater significance in filtering performance; still, because active filters also have maintenance issues, resonance effects, and less effect in large scale loads, the combined effects of active and passive power filters have gained prominence in recent times [2,4,6,7].…”
Section: Introductionmentioning
confidence: 99%
“…Generally, in mitigating current harmonics, the APF cancels the low-order harmonics while the passive filter eliminates the others [44,45]. Nevertheless, there are many HPF topologies, as discussed in [4,44,67,68]. Furthermore, HPFs allow suppressing harmonic resonances in industrial facilities with tuned passive filters installed [69].…”
Section: Types Of Filtersmentioning
confidence: 99%
“…Harmonic spectral components vary based on amplitude and output frequency in a cyclo-converter drive. Inter harmonics that are present near the fundamental frequency increases to about 40% of the fundamental when cyclo-converter drive is operated and it leads to high power losses in transformer [9][10][11].In direct AC-AC Power conversion systems, STATCOMs (static compensators), Active Filters and Hybrid Filters are employed to compensate the effect of the harmonics and inter harmonics produced in cyclo-converter [12][13][14].…”
Section: Introductionmentioning
confidence: 99%