2023
DOI: 10.3390/su151713098
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Seismic Performance of Masonry Stone Pagoda: Dynamic Centrifuge Test and Numerical Simulation Analysis

Gayoon Lee,
Heon-Joon Park,
Khoa V. A. Pham
et al.

Abstract: This study provides a comparison of results from dynamic centrifuge tests and a finite element analysis model to confirm the behavior of a representative Korean stone pagoda cultural heritage structure against earthquakes. The indirect stiffness or physical state of the structure was estimated by measuring the natural frequency of the masonry stone pagoda. The actual natural frequency of the stone pagoda was measured to be 4.5 Hz. It was determined to have a lower natural frequency than other stone pagodas of … Show more