2013
DOI: 10.3791/50172-v
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 7 publications
0
9
0
Order By: Relevance
“…Lung mechanics such as lung resistance, lung compliance, and tissue elastance were measured in anesthetized mice. Mice were mechanically ventilated with a tidal volume of 10 ml/kg and a positive end-expiratory pressure of 2 cm H 2 O using the flexiVent (Scireq, Montreal, QC, Canada) ventilation setup as previously described in McGovern et al (30).…”
Section: Measurement Of Lung Mechanicsmentioning
confidence: 99%
“…Lung mechanics such as lung resistance, lung compliance, and tissue elastance were measured in anesthetized mice. Mice were mechanically ventilated with a tidal volume of 10 ml/kg and a positive end-expiratory pressure of 2 cm H 2 O using the flexiVent (Scireq, Montreal, QC, Canada) ventilation setup as previously described in McGovern et al (30).…”
Section: Measurement Of Lung Mechanicsmentioning
confidence: 99%
“…Lung function assessments were conducted using a flexiVentÂź mechanical respirator (flexiVentÂź, SCIREQ, Montreal, PQ, Canada) according to SCIREQ Scientific Respiratory Equipment Inc.'s published protocols 49 . FlexiVentÂź enabled the measurement of lung elastance which is a functional parameter derived from the pressure‐driven pressure–volume loops.…”
Section: Methodsmentioning
confidence: 99%
“…Ventilation studies were performed using flexiVent (SCIREQ Inc.). FlexiVent is a murine ventilation system based on the linear single‐frequency forced oscillation technique (FOT), as previously described 10,11 . This FOT system was used to determine inspiratory capacity (IC) and large airway resistance in CDH and control rodents.…”
Section: Methodsmentioning
confidence: 99%
“…FlexiVent is a murine ventilation system based on the linear single-frequency forced oscillation technique (FOT), as previously described. 10,11 This FOT system was used to determine inspiratory capacity (IC) and large airway resistance in CDH and control rodents. Newborn pups were anesthetized with inhalational isoflurane (4%; Clipper Distributing Company, LLC).…”
Section: Oxygenation and Ventilation Datamentioning
confidence: 99%