Computers in Cardiology 1997
DOI: 10.1109/cic.1997.647918
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of respiratory influences on left ventricular function by means of echocardiographic approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 3 publications
0
9
0
Order By: Relevance
“…To evaluate the ability of the dynamic TW algorithm to reduce the interbeat variability, for each NY subject the same sequence of 64 consecutive beats utilised in protocol 2 was analysed as follows: the indices ESV, EDV, SV, EF%, PFR, PAFR, PER and tpVR were automatically obtained on a beat-to-beat basis (PORTA et al, 1997;CAIANI et al, 2000b), and their mean value, SD and var% were calculated.…”
Section: Protocol 4: Comparison Of Awl6 Variability With Beat-to-beatmentioning
confidence: 99%
See 1 more Smart Citation
“…To evaluate the ability of the dynamic TW algorithm to reduce the interbeat variability, for each NY subject the same sequence of 64 consecutive beats utilised in protocol 2 was analysed as follows: the indices ESV, EDV, SV, EF%, PFR, PAFR, PER and tpVR were automatically obtained on a beat-to-beat basis (PORTA et al, 1997;CAIANI et al, 2000b), and their mean value, SD and var% were calculated.…”
Section: Protocol 4: Comparison Of Awl6 Variability With Beat-to-beatmentioning
confidence: 99%
“…The detection of the ESV was based on the detection of the R-wave on the ECG (PORTA et al, 1997). The minimum of the LV volume signal was searched inside a time window lasting a user-defined percentage of the mean heart period and starting from the R peak.…”
Section: Data Acquisitionmentioning
confidence: 99%
“…The beat-to-beat variability series were extracted (figure 1) as follows (Porta et al 1997). The RR interval was obtained as the time interval between two consecutive R peaks, detected by a traditional derivative threshold procedure.…”
Section: Extraction Of the Left Ventricular Function Parametersmentioning
confidence: 99%
“…In this perspective, an automated algorithm (Porta et al 1997) for the beat-to-beat extraction of LV function parameters from a few minutes continuous acquisition of LV volume waveforms was developed and the high-frequency (HF) respiratory spectral component (Akselrod et al 1981, Pagani et al 1986, Malliani et al 1991 was extracted by means of autoregressive spectral analysis. The study has been carried out on a group of normal young subjects and a group of normal older subjects, to evaluate the effects of ageing on respiratoryrelated power evaluated on the extracted beat-to-beat series of LV function parameters.…”
Section: Introductionmentioning
confidence: 99%
“…For example, the 2-dimensional automated border detection (ABD) system used in the Hewlett Packard SONOS 2500 provides a detection of the LV endocardial border from the ultrasound scan plane which is highly operator-dependent 19 . In fact, the process of manual outlining and gain setting necessary in most ABD systems is time consuming, tedious, and very subjective 5,12,15 , as is indicated by the general lack of reproducibility between inter-and intra-observers. The objective of the work reported in this paper is to fully automate the procedure of extracting the LV boundary in 2-D echo sequences.…”
Section: Introductionmentioning
confidence: 99%