2005
DOI: 10.1016/j.jcms.2004.07.004
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of quality of reformatted images from two cone-beam computed tomographic systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
27
0
6

Year Published

2007
2007
2015
2015

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 38 publications
(33 citation statements)
references
References 21 publications
0
27
0
6
Order By: Relevance
“…The level of radiation exposure is lower, and the metal artefacts are reduced. 25 CBCT with a limited volume is well suited for the diagnosis of periapical pathology, as used in planning for endodontic surgery. 3,26,27 Limited volume CBCT provides images at high spatial resolution, with low radiation doses and displaying accurate measurements.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The level of radiation exposure is lower, and the metal artefacts are reduced. 25 CBCT with a limited volume is well suited for the diagnosis of periapical pathology, as used in planning for endodontic surgery. 3,26,27 Limited volume CBCT provides images at high spatial resolution, with low radiation doses and displaying accurate measurements.…”
Section: Discussionmentioning
confidence: 99%
“…26,28 Its disadvantage is the lack of tissue information. 25 Segmentation in CBCT is often more complex because the image is noisier than in MSCT, owing to lower bone signal-to-noise ratio. The image contrast between the tooth root and the alveolar bone is lower in CBCT.…”
Section: Discussionmentioning
confidence: 99%
“…When combined with dedicated software packages, it can provide practitioners with a complete solution for demanding tasks (Mozzo et al, 1998;Sukovic, 2003;Schulze et al, 2005).…”
Section: Discussionmentioning
confidence: 99%
“…When compared with other methods of tomographic imaging, CBCT is characterized by rapid volumetric image acquisition from a single low radiation dose scan of the patient. CBCT, also known as true volumetric computed tomography (TVCT) designed for use in dental imaging of osseous structures has been introduced (Rothman, 1998;Mozzo et al, 1998;Schulze et al, 2005). The first available and now well-established CBCT system, the NewTom is an example of such a CBCT machine dedicated to dental and maxillofacial imaging, particularly for surgical and/or prosthetics implant planning in the field of dentistry.…”
Section: Introductionmentioning
confidence: 99%
“…Diferentes estruturas anatômicas foram analisadas por dez observadores nas reconstruções multiplanares. Em relação à qualidade de imagem, não houve diferença estatisticamente significativa entre os dois aparelhos, tendo apenas o canal mandibular e o osso trabecular, na reconstrução ortogonal, apresentado uma qualidade de imagem maior no TCFC NewTom 9000, para o qual, no protoloco de aquisição, o voxel foi menor que para o Siremobil Iso-C3D 18 .…”
Section: Revisão De Literaturaunclassified