Evaluation of PIRs Post-Fire Pull-Out Strength in Concrete Exposed to ISO 834-1 Fire

Abstract: Post-installed rebars (PIRs) using mortar can offer bond strength at ambient temperature equal or higher to that of cast-in place rebars. However, high temperatures have the effect of weakening the bond, typically governed by the chemical and physical properties of the mortar which is often sensitive to temperature increase. Therefore, the behavior of PIRs in a fire situation becomes vulnerable. Moreover, after exposure of PIRs to high temperature, the heat transfer continues during the post-fire phase, which … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…There has been much valuable work conducted in the field of adhesive and mechanical anchors intended for use in concrete, and concrete anchors have been the subject matter of many valuable papers. However, a detailed insight into those documents reveals that most of the papers are devoted to the anchor’s extraction strength, i.e., pull-out resistance [ 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 ], and to cast-in anchors, i.e., anchors installed in new structures, before pouring the concrete [ 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 ]. As a result, only a minor part of those papers deals with the anchors’ shear strength and with post-installed anchors.…”
Section: Introduction: State-of-the-art About Post-installed Concrete...mentioning
confidence: 99%
“…There has been much valuable work conducted in the field of adhesive and mechanical anchors intended for use in concrete, and concrete anchors have been the subject matter of many valuable papers. However, a detailed insight into those documents reveals that most of the papers are devoted to the anchor’s extraction strength, i.e., pull-out resistance [ 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 ], and to cast-in anchors, i.e., anchors installed in new structures, before pouring the concrete [ 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 ]. As a result, only a minor part of those papers deals with the anchors’ shear strength and with post-installed anchors.…”
Section: Introduction: State-of-the-art About Post-installed Concrete...mentioning
confidence: 99%
“…The effect of high temperatures on the bond strength of post-installed rebars (PIRs) made with polymeric mortars was studied by Chehade et al [ 9 ]. The evolution of the pull-out capacity of PIRs was assessed during the post-fire phase after exposure to ISO 834-1 standard fire conditions.…”
mentioning
confidence: 99%