Evaluation of Pipe Thickness by Magnetic Hammer Test with a Tunnel Magnetoresistive Sensor

Jun Ito,
Yudai Igarashi,
Ryota Odagiri
et al.

Abstract: A new nondestructive inspection method, the magnetic hammer test (MHT), which uses a compact and highly sensitive tunnel magnetoresistance (TMR) sensor, is proposed. This method complements the magnetic flux leakage method and eliminates the issues of the hammer test. It can therefore detect weak magnetic fields generated by the natural vibration of a pipe with a high signal-to-noise ratio. In this study, several steel pipes with different wall thicknesses were measured using a TMR sensor to demonstrate the su… Show more