2017
DOI: 10.1186/s12880-017-0204-x
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of patients with painful total hip arthroplasty using combined single photon emission tomography and conventional computerized tomography (SPECT/CT) – a comparison of semi-quantitative versus 3D volumetric quantitative measurements

Abstract: BackgroundIt was the primary purpose of our study to evaluate the inter- and intra-observer reliability of a standardized SPECT/CT algorithm for evaluating patients with painful primary total hip arthroplasty (THA). The secondary purpose was a comparison of semi-quantitative and 3D volumetric quantification method for assessment of bone tracer uptake (BTU) in those patients.MethodsA novel SPECT/CT localization scheme consisting of 14 femoral and 4 acetabular regions on standardized axial and coronal slices was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 36 publications
0
6
0
Order By: Relevance
“…Generally, in traditional nuclear medicine imaging, single photon emission computed tomography (SPECT) modality has been used for qualitative diagnosis by visual evaluation of radioactive distribution. For quantitative analysis, the target/nontarget (T/NT) ratio calculated from counts of their regions of interest (ROI) was widely used in SPECT modality, which was known as the semiquantitative analysis [1, 2]. Positron emission tomography (PET) was regarded as the only modality capable of absolute quantitative analysis in the past [35].…”
Section: Introductionmentioning
confidence: 99%
“…Generally, in traditional nuclear medicine imaging, single photon emission computed tomography (SPECT) modality has been used for qualitative diagnosis by visual evaluation of radioactive distribution. For quantitative analysis, the target/nontarget (T/NT) ratio calculated from counts of their regions of interest (ROI) was widely used in SPECT modality, which was known as the semiquantitative analysis [1, 2]. Positron emission tomography (PET) was regarded as the only modality capable of absolute quantitative analysis in the past [35].…”
Section: Introductionmentioning
confidence: 99%
“…A previous study showed that when SPECT/CT was added, inter-observer agreement regarding the location of infectious foci increased from κ = 0.68 to κ = 1.0 in in the assessment of osteomyelitis [11]. In agreement with the first clinical studies, 4 studies demonstrated "excellent" intra-and inter-observer agreement when SPECT/CT was added in the interpretation of symptomatic hip and knee arthroplasties [30][31][32][33]. However, these studies did not correlate the nuclear imaging results with surgical findings or clinical follow-up whether the prosthesis was loose or not.…”
Section: Bone Scintigraphy and Spect/ctmentioning
confidence: 57%
“…Only few studies investigated the relative intensity of periprosthetic bone metabolism with bone scintigraphy and bone SPECT/CT referencing the periprosthetic activity with ROIs of the femur [ 15 17 ] and found a good interreader agreement for such a standardized protocol [ 16 , 17 ]. To our knowledge, there is only one available study applying quantification of periprosthetic uptake for the diagnosis of aseptic loosening published 2008 by Klett et al [ 15 ].…”
Section: Discussionmentioning
confidence: 99%
“…The main focus of the diagnostic criteria of prosthetic loosening in SPECT/CT lies in the distribution of elevated bone metabolism around the prosthetic implant. Only few studies investigated the diagnostic value of uptake intensity of periprosthetic bone [ 15 17 ] with promising results although only relative semiquantitative uptake measures were used. Recently, a new generation of SPECT/CT scanners and reconstruction algorithms of SPECT data was introduced that allows the absolute quantification of tracer uptake [ 18 ] in clinical routine.…”
Section: Introductionmentioning
confidence: 99%