2017
DOI: 10.1177/0003702817693231
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Optical Depths and Self-Absorption of Strontium and Aluminum Emission Lines in Laser-Induced Breakdown Spectroscopy (LIBS)

Abstract: Laser-induced breakdown spectroscopy (LIBS) is a widely used laser spectroscopic technique in various fields, such as material science, forensic science, biological science, and the chemical and pharmaceutical industries. In most LIBS work, the analysis is performed using radiative transitions from atomic emissions. In this study, the plasma temperature and the product [Formula: see text] (the number density N and the absorption path length [Formula: see text]) were determined to evaluate the optical depths an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 24 publications
0
10
0
Order By: Relevance
“…A 1024 × 1024 intensified charge-coupled device (ICCD) detector was used for data acquisition. 7,11,20
Figure 1.The experimental setup used for LIBS. BD, beam dump; DM, dichroic mirror; PC, personal computer.
…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…A 1024 × 1024 intensified charge-coupled device (ICCD) detector was used for data acquisition. 7,11,20
Figure 1.The experimental setup used for LIBS. BD, beam dump; DM, dichroic mirror; PC, personal computer.
…”
Section: Methodsmentioning
confidence: 99%
“…A 1024 Â 1024 intensified charge-coupled device (ICCD) detector was used for data acquisition. 7,11,20 A synchronization controller system, which is a programmable time controller, was used to control the gate delay time and gate width time; it is triggered by a pulse from the laser Q-switch to synchronize data acquisition. The spectra were recorded and processed using Andor iStar software (version 4.29).…”
Section: Experimental Details Experimental Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…In recent decades, considerable attempts have been made to handle this self-absorption effect. [18][19][20] To overwhelm this problem, Sun and Yu coined an intensity correction method known as the internal reference self-absorption correction (IRSAC) method. 21 After intensity correction using the selfabsorption coefficient, we redrew the Boltzmann plot.…”
Section: Introductionmentioning
confidence: 99%
“…Alfarraj et al. 21 used the plasma temperature and the product Nl (the number density N and the absorption path length l ) to evaluated the optical depths and the self-absorption of Sr and Al lines by the COG method and compare the results under different experimental conditions (gate delay time, gate width time, and laser energy). This method can help develop calibration model for samples with high species concentrations.…”
Section: Introductionmentioning
confidence: 99%