2007
DOI: 10.1088/0031-9155/52/3/011
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation

Abstract: On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. Here we evaluate the achievable accuracy in using a kV CBCT for dose calculation. Relative electron density as a function of HU was obtained for both planning CT (pCT) and CBCT using a Catphan-600 calibration phantom. The CBCT calibration stability was monitored weekly for 8 consecutive weeks. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

12
292
0
4

Year Published

2016
2016
2018
2018

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 269 publications
(308 citation statements)
references
References 33 publications
12
292
0
4
Order By: Relevance
“…Although many researchers7, 8, 9, 10, 11, 12, 13 have investigated CBCT‐based dose calculations and their use in replanning or online adaptive planning, clinical implementation has remained challenging because of the complexity of the technique or inability to achieve the accuracy required by treatment planning. In this study, we assessed the accuracy of the CBCT‐based dose calculations using patient‐specific stepwise HU‐to‐density curves and investigated the feasibility of using this method to determine replanning time.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Although many researchers7, 8, 9, 10, 11, 12, 13 have investigated CBCT‐based dose calculations and their use in replanning or online adaptive planning, clinical implementation has remained challenging because of the complexity of the technique or inability to achieve the accuracy required by treatment planning. In this study, we assessed the accuracy of the CBCT‐based dose calculations using patient‐specific stepwise HU‐to‐density curves and investigated the feasibility of using this method to determine replanning time.…”
Section: Discussionmentioning
confidence: 99%
“…Onboard kV cone‐beam CT (CBCT) is now widely available, and CBCT‐based dose calculation makes it possible to evaluate dosimetric change during the course of treatment. Although kV CBCT technology is mainly used to set up patients and localize anatomy, its potential for use in dose calculation has been recognized and reported 7, 8, 9, 10. Dose calculation accuracy using CBCT images has been evaluated by investigators 8, 9, 11, 12, 13.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations