2022
DOI: 10.1371/journal.pone.0265844
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of ocular biometry in primary angle-closure disease with two swept source optical coherence tomography devices

Abstract: Purpose To investigate agreement between 2 swept source OCT biometers, IOL Master700 and Anterion, in various ocular biometry and intraocular lens (IOL) calculations of primary angle-closure disease (PACD). Setting Rajavithi Hospital, Bangkok, Thailand. Design Prospective comparative study. Methods This study conducted in a tertiary eye care center involving biometric measurements obtained with 2 devices in phakic eye with diagnosis of PACD. Mean difference and intraclass correlation coefficient (ICC) wi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 29 publications
1
2
0
Order By: Relevance
“…But all these conclusions should be drawn with care as none of the comparison appeared statistically significant. For network meta-analysis, BUII achieved better postoperative outcomes than other formulae based on MAE, consistent with previous studies and current clinical experience [8]. However, BUII and some other seemingly preferable formulas like RBF 3.0 and LSF had relatively wide confidence intervals, indicating their instability when applied for PAC/PACG eyes.…”
Section: Plos Onesupporting
confidence: 85%
See 1 more Smart Citation
“…But all these conclusions should be drawn with care as none of the comparison appeared statistically significant. For network meta-analysis, BUII achieved better postoperative outcomes than other formulae based on MAE, consistent with previous studies and current clinical experience [8]. However, BUII and some other seemingly preferable formulas like RBF 3.0 and LSF had relatively wide confidence intervals, indicating their instability when applied for PAC/PACG eyes.…”
Section: Plos Onesupporting
confidence: 85%
“…Along with well-accepted precision of ocular biometry, accuracy of manufacturer IOL power quality control and the now-mature surgical techniques, the accuracy of IOL power calculation becomes the most essential factor for achieving the target refraction post-operatively. A dozen formulas for IOL power calculation have been established with diverse core principles on the basis of normal eyes since 1980s, yet the accuracy varies [7][8][9]. Theoretically, it could be well imagined that discrepancies in IOL prediction would occur when these formulas, especially regressive ones [10], were applied to special population with unusual ocular biometric parameters, e.g., significantly shallow anterior chamber (AC), thick lens and short axial length (AL) [11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…The IOLMaster 700, which is based on swept-source OCT, offers an image-based measurement that shows the entire longitudinal section of the eye. We conducted a thorough examination where we precisely measured the ASL and PSL using the IOLMaster 700 [13,14].…”
Section: Discussionmentioning