2014
DOI: 10.1039/c4ja00195h
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of mixing devices and connection mode in the determination of Pb in glass using online isotope dilution laser ablation-ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…Future work will study the feasibility of the developed strategy for quantitative imaging of real biological samples on a pixel-by-pixel basis, targeting "hot spot" regions of Fe that have been identied by external calibration strategies or complementary techniques such as XRF. Focus will be on the improvement of the efficiency of online mixing of spike and sample 37 and the investigation of the suitability of different materials as matrix matching calibration standards. This will be achieved by determining their respective mass ow rates in comparison to real sample tissues.…”
Section: Discussionmentioning
confidence: 99%
“…Future work will study the feasibility of the developed strategy for quantitative imaging of real biological samples on a pixel-by-pixel basis, targeting "hot spot" regions of Fe that have been identied by external calibration strategies or complementary techniques such as XRF. Focus will be on the improvement of the efficiency of online mixing of spike and sample 37 and the investigation of the suitability of different materials as matrix matching calibration standards. This will be achieved by determining their respective mass ow rates in comparison to real sample tissues.…”
Section: Discussionmentioning
confidence: 99%
“…Feng and Wang 113 provided an assessment of in-line mixing devices used to combine laser ablated product with a 207 Pb spike, prior to measurement of Pb concentration by isotope dilution ICP-MS. Analysis of NIST glasses demonstrated that Pb isotope ratios measured on the combined aerosols from a membrane desolvator and laser ablation were most stable when mixing was completed in a spherical chamber with a sphere-centred exit nozzle.…”
Section: Isotope Dilution Analysis (Ida)mentioning
confidence: 99%
“…However the application of on-line ID in the direct analysis of glasses by LA-ICP-MS represents a more complex challenge because of the potential for poor mixing of the spike sample aerosol. 198 In order to obtain the good isotope equilibrium needed for ID-LA-ICP-MS, four different mixing devices (including pre-and postcell introduction of the isotope spike) were designed and evaluated for application to the determination of Pb in silicate glasses. A pre-cell connection mode provided optimum performance in respect of consistency of the blended Pb isotopes, delivered good precision in the measurement of the 208 Pb/ 207 Pb isotope ratio, and exhibited signicantly less loss of sensitivity than in post cell mode.…”
Section: Glassesmentioning
confidence: 99%