2007
DOI: 10.1002/jmri.21236
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of manual and automatic segmentation of the mouse heart from CINE MR images

Abstract: Purpose:To compare global functional parameters determined from a stack of cinematographic MR images of mouse heart by a manual segmentation and an automatic segmentation algorithm. Materials and Methods:The manual and automatic segmentation results of 22 mouse hearts were compared. The automatic segmentation was based on propagation of a minimum cost algorithm in polar space starting from manually drawn contours in one heart phase. Intra-and interobserver variability as well as validity of the automatic segme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
38
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 34 publications
(41 citation statements)
references
References 32 publications
2
38
1
Order By: Relevance
“…Even though MRI is often considered the gold standard for the assessment of LV volumes and function, measurements of EDV, ESV, and EF are not without error and depend on the analysis software (23,29,30). Because MRI works on a stack of 2-dimensional slices and not on a true 3-dimensional dataset, the assessment of LV shortening can be a problem.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Even though MRI is often considered the gold standard for the assessment of LV volumes and function, measurements of EDV, ESV, and EF are not without error and depend on the analysis software (23,29,30). Because MRI works on a stack of 2-dimensional slices and not on a true 3-dimensional dataset, the assessment of LV shortening can be a problem.…”
Section: Discussionmentioning
confidence: 99%
“…The cine MR images were analyzed on a slice-by-slice basis using the semiautomatic validated segmentation software CAAS MRV FARM (Pie Medical Imaging) to obtain EDV, ESV, and EF (23,24). Free papillary muscles were not included into the myocardial compartment.…”
Section: Data Processingmentioning
confidence: 99%
“…18 LV mass was calculated by multiplying the end-diastolic myocardial wall volume with a myocardial density of 1.05 g/mL. 19 End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were calculated as described previously.…”
Section: Image Analysismentioning
confidence: 99%
“…19 End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were calculated as described previously. 18 Cardiac output (CO) was calculated by multiplying the SV with the average heart rate. Peak ejection rate and peak filling rate were determined from the high temporal resolution cine series as, respectively, the minimum and maximum in the time-derivative of the LV cavity volume.…”
Section: Image Analysismentioning
confidence: 99%
“…Few results have been reported in mice (7,8). In our experience, user correction of errors arising from automated analysis requires that user interaction be intrinsic, intuitive, and minimal.…”
mentioning
confidence: 99%