2018 AEIT International Annual Conference 2018
DOI: 10.23919/aeit.2018.8577302
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Joule Power Losses Reduction in Overhead Lines with Innovative Conductors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…As detailed in [13], the load-duration curve can be discretized in segments having a given duration ∆τ, so that the active power loss ∆p is deduced for every load power value and the annual joule losses (AJL) energy can be calculated by just multiplying ∆p by the respective time step. At this point, by assuming a constant electricity generation cost (40 €/MWh is used in this study [32]), it is possible to have an indication of the Annual Cost of Losses (ACL), calculated as ACL = AJL · C mL (€) (13) which can be actualized for each year in the OHL's lifetime by means of a discount rate i (here assumed as 5%) as in (14):…”
Section: Distribution Network Ohlsmentioning
confidence: 99%
See 2 more Smart Citations
“…As detailed in [13], the load-duration curve can be discretized in segments having a given duration ∆τ, so that the active power loss ∆p is deduced for every load power value and the annual joule losses (AJL) energy can be calculated by just multiplying ∆p by the respective time step. At this point, by assuming a constant electricity generation cost (40 €/MWh is used in this study [32]), it is possible to have an indication of the Annual Cost of Losses (ACL), calculated as ACL = AJL · C mL (€) (13) which can be actualized for each year in the OHL's lifetime by means of a discount rate i (here assumed as 5%) as in (14):…”
Section: Distribution Network Ohlsmentioning
confidence: 99%
“…On the other hand, substituting the currently installed standard conductors with others having a larger cross-section may cause an overall weight increase, resulting in the necessity of adapting the towers, dramatically increasing the investment costs.The project CALAJOULE, cofinanced by the Italian Ministry of Economic Development in the framework of the "Ricerca di Sistema" program, aims at proposing innovative conductor prototypes for overhead lines for the containment of Joule power losses. This paper aims at disseminating all the main findings and conclusions of the CALAJOULE project, whereas some preliminary results had already been presented in some previously published papers [12,13].The main difference with respect to other literature contributions regarding innovative overhead conductors is that the developed solutions have been ideated not to increase current ratings and power flows but to lessen the Joule power losses. The positive economic and environmental impacts have been evaluated quantitatively for paradigmatic overhead lines.…”
mentioning
confidence: 99%
See 1 more Smart Citation