“…In some cases, just a dilution step can be enough, as can be exemplified by fluorine determination 32,34 in water without pretreatment for further analysis by ICP-QQQ. 32,34 Moreover, the analysis of crude oil, 44 drug substances, 22 polyglycerol, 154 seaweed, 23 and urine 8 samples can be performed employing only a preliminary dilution with a suitable solvent (for fluorine, 22 chlorine, 22,44 bromine, 22 and iodine 8,22,23,109 determination by ICP-MS). On the other hand, only a filtration step using specific membranes can be required for further iodine determination in milk, 85 urine, 85 and water 49 by ICP-MS.…”
Section: Sample Preparation Methods For Further Halogen Determinatimentioning
confidence: 99%
See 3 more Smart Citations
“…In some cases, just a dilution step can be enough, as can be exemplified by fluorine determination 32,34 in water without pretreatment for further analysis by ICP-QQQ. 32,34 Moreover, the analysis of crude oil, 44 drug substances, 22 polyglycerol, 154 seaweed, 23 and urine 8 samples can be performed employing only a preliminary dilution with a suitable solvent (for fluorine, 22 chlorine, 22,44 bromine, 22 and iodine 8,22,23,109 determination by ICP-MS). On the other hand, only a filtration step using specific membranes can be required for further iodine determination in milk, 85 urine, 85 and water 49 by ICP-MS.…”
Section: Sample Preparation Methods For Further Halogen Determinatimentioning
confidence: 99%
“…Hence, the use of an internal standard (IS) has been a well-documented strategy to overcome instrument instability and non-spectral interferences, as well as to increase the precision of the measurements. 77 Internal standards have mainly been used for bromine and iodine determination, and several elements have been evaluated for this purpose, such as Te 8,23,37,46,47,51,52,54,65,72,76,78 and Sb 72,75,76 for iodine determination. On the other hand, Cs, 50,56,68,79 , In [80][81][82][83] Sb, 75,84 Sc, 84 Te, 65 and Y 46,47 have been applied for bromine determination.…”
Section: Internal Standards and Isotope Dilution For Halogen Determmentioning
confidence: 99%
See 2 more Smart Citations
“…A SES score has been calculated based on the education level, major professional occupation and income [17] [18]. Thus, two levels were adopted for each Open Journal of Epidemiology of its variables with partial scores of 0 and 1 respectively (education level ≤ primary versus education level > primary), (non-remunerated versus remunerated), (income < guaranteed inter-professional minimum wage (GIMW) versus income ≥ GIMW (GIMW is ≈ US$80 in 2014)).…”
Section: C) Socio-economic Status (Ses)mentioning
confidence: 99%