2018
DOI: 10.5505/ktd.2018.37928
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Integrated Pulmonary Index monitoring during sedation for Deep Brain Stimulation

Abstract: De er ri in n B Be ey yi in n S St ti im mü ül la as sy yo on nu u ((D DB BS S)) u uy yg gu ul la an na an n h ha as st ta al la ar rı ın n e en nt te eg gr re e p pu ul lm mo on ne er r i in nd de ex x ((I IP PI I)) m mo on ni it tö ör ri iz za as sy yo on nu u i il le e t ta ak ki ib bi i E Ev va al lu ua at ti io on n o of f I In nt te eg gr ra at te ed d P Pu ul lm mo on na ar ry y I In nd de ex x m mo on ni it to or ri in ng g d du ur ri in ng g s se ed da at ti io on n f fo or r D De ee ep p B Br ra ai i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 8 publications
0
2
0
Order By: Relevance
“…Data obtained from the capnograph monitor's nasal probe (end-tidal carbon dioxide (EtCO2), respiratory rate (SS) and the finger probe (SPO2 and HR) are used by the IPI monitor (Capnostream® 20p/Covidien; Medtronic, Dublin, Ireland) to calculate a score that indicates the respiratory condition of the patient. IPI values range from 1 to 10, with values between 7 and 10 reflecting acceptable respiratory parameters and values below 7 requiring attention (Table 1 ) [ 10 , 11 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Data obtained from the capnograph monitor's nasal probe (end-tidal carbon dioxide (EtCO2), respiratory rate (SS) and the finger probe (SPO2 and HR) are used by the IPI monitor (Capnostream® 20p/Covidien; Medtronic, Dublin, Ireland) to calculate a score that indicates the respiratory condition of the patient. IPI values range from 1 to 10, with values between 7 and 10 reflecting acceptable respiratory parameters and values below 7 requiring attention (Table 1 ) [ 10 , 11 ].…”
Section: Methodsmentioning
confidence: 99%
“…The Integrated Pulmonary Index (IPI) algorithm provides a single value that represents respiratory parameters that include end-tidal carbon dioxide concentration (EtCO2), respiratory rate (SS), heart rate (HR), and peripheral oxygen saturation (SpO2). IPI enables the clinician to assess the patient's respiratory status and determine the need for intervention quickly [ 1 , 10 , 11 ]. In addition, the Food and Drug Administration of the United States (FDA) states that IPI monitors can be used to monitor respiratory parameters in sedated patients [ 12 , 13 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation