2016
DOI: 10.1111/pan.13001
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of I‐Gel size 2 airway in different degrees of neck flexion in anesthetized children – a prospective, self‐controlled trial

Abstract: We conclude that 15° neck flexion can safely be applied without compromising ventilation with the I-Gel in anesthetized paralyzed children. However, Flexion of 30° or more warrants caution or the use of alternative devices like an endotracheal tube due to increase in PIP and worsening of ventilation score.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
17
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(17 citation statements)
references
References 16 publications
0
17
0
Order By: Relevance
“…SADs used for the included studies were as follows: the air-Q self-pressurizing airway was used in 1 study,[4] the i-gel was used in 5 studies,[1012,14,23] the LMA Supreme was used in 2 studies,[6,23] the laryngeal tube was used in 1 study,[9] the laryngeal tube suction was used in 4 studies,[6,8,17,24] the LMA Proseal was used in 6 studies,[8,11,15,16,24,25] the Cobra perilaryngeal airway was used in 1 study,[8] the LMA Classic was used in 5 studies,[5,7,9,13,25] and the LMA Flexible was used in 2 studies. [7,13] The reinforced LMA was regarded as the LMA Flexible.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…SADs used for the included studies were as follows: the air-Q self-pressurizing airway was used in 1 study,[4] the i-gel was used in 5 studies,[1012,14,23] the LMA Supreme was used in 2 studies,[6,23] the laryngeal tube was used in 1 study,[9] the laryngeal tube suction was used in 4 studies,[6,8,17,24] the LMA Proseal was used in 6 studies,[8,11,15,16,24,25] the Cobra perilaryngeal airway was used in 1 study,[8] the LMA Classic was used in 5 studies,[5,7,9,13,25] and the LMA Flexible was used in 2 studies. [7,13] The reinforced LMA was regarded as the LMA Flexible.…”
Section: Resultsmentioning
confidence: 99%
“…[4,8] Because the pharyngeal anatomy changes according to the head and neck position, the performance of SADs may be affected, including the sealing function, ventilation, and fibreoptic view. [4,912]…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Sir—With great interest, we read the article entitled ‘Evaluation of I‐Gel™ size 2 airway in different degrees of neck flexion in anesthetized children—a prospective, self‐controlled trial’ . We acknowledge this study is interesting and meaningful for our clinical work.…”
mentioning
confidence: 99%