2003
DOI: 10.1373/49.4.581
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Human Serum Albumin Cobalt Binding Assay for the Assessment of Myocardial Ischemia and Myocardial Infarction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

7
139
0
16

Year Published

2008
2008
2013
2013

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 235 publications
(175 citation statements)
references
References 13 publications
7
139
0
16
Order By: Relevance
“…There are several sites on the protein that have the ability to bind metals, though most interest to date has focused on the N-terminal region. 13,18 IMA was determined according to the cobalt-binding assay method of Bhagavan et al 13 Briefly, plasma was incubated with a cobalt chloride (1 g/L, 10 minutes) and dithiothreitol (1.5 g/L, 2 minutes) before dilution in saline prior to measurement at 470 nm in a spectrophotometer (Agilent 8453 Diode Array, Agilent, UK). IMA was calculated from the difference between samples measured with and without dithiothreitol.…”
Section: Measurement Of Albumin Functionmentioning
confidence: 99%
See 1 more Smart Citation
“…There are several sites on the protein that have the ability to bind metals, though most interest to date has focused on the N-terminal region. 13,18 IMA was determined according to the cobalt-binding assay method of Bhagavan et al 13 Briefly, plasma was incubated with a cobalt chloride (1 g/L, 10 minutes) and dithiothreitol (1.5 g/L, 2 minutes) before dilution in saline prior to measurement at 470 nm in a spectrophotometer (Agilent 8453 Diode Array, Agilent, UK). IMA was calculated from the difference between samples measured with and without dithiothreitol.…”
Section: Measurement Of Albumin Functionmentioning
confidence: 99%
“…Electron paramagnetic resonance (EPR) spectroscopy was used to perform detailed analyses of the individual binding sites that are associated with the main function of albumin. Ischemia-modified albumin, 13 a test that measures the cobalt-binding capacity of albumin, was measured in the same cohort to determine whether this simpler test could be used as a biomarker to determine prognosis in patients with acute-on-chronic liver failure (ACLF). In addition, we wanted to determine whether dialysis against an albumin solution using the MARS system has any ability to affect albumin functional capacity in patients with ACLF.…”
mentioning
confidence: 99%
“…We evaluated the role of ischemia-modified albumin (IMA), a new marker of ischemia, in patients with ACS. IMA is produced during an ischemic attack and is present in blood in easily detectable concentrations (12)(13)(14).…”
Section: Introductionmentioning
confidence: 99%
“…This alteration can be measured by the albumin cobalt-binding (ACB) test. 23,24 Several studies have shown that IMA is an early sensitive marker for the diagnosis of reversible ischemia. 25,26 However, a recent study found frequent false-positive results and a low specificity with this test.…”
mentioning
confidence: 99%