Evaluation of Heat Release Performance of Swaged- and Extruded-type Heat Sink Used in Industrial Inverter

Abstract: In this experiment, we investigated the performance of two types of heat sink, swaged-and extruded-type, used in the inverter of industrial electricity generator. The swaged-type heat sink has 62 fins, and the extruded-type has 38 fins having the same dimension as that of the swaged-type. But the extruded-type heat sink maintains the same heat transfer area by the laterally waved surface which has 1 mm in radius. As a result, the swaged-and extruded-type heat sinks released 70.7% and 63.8% of the heat incoming… Show more