2005
DOI: 10.1373/clinchem.2005.048520
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Glucose-6-Phosphate Dehydrogenase Stability in Blood Samples under Different Collection and Storage Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
8
0
2

Year Published

2006
2006
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(11 citation statements)
references
References 3 publications
1
8
0
2
Order By: Relevance
“…These are typically in low prevalence in the population and require significant screening to identify patients with these G6PD activity characteristics. Unfortunately, when these specimens are obtained they must be tested within a short time frame (seven to 14 days) [17]. Establishing a specimen bank enriched for specimens with intermediate G6PD activity, with deficient G6PD activity, and from confirmed heterozygous females would be of great value to both the development of tests for G6PD deficiency and to their early evaluation.…”
Section: Discussionmentioning
confidence: 99%
“…These are typically in low prevalence in the population and require significant screening to identify patients with these G6PD activity characteristics. Unfortunately, when these specimens are obtained they must be tested within a short time frame (seven to 14 days) [17]. Establishing a specimen bank enriched for specimens with intermediate G6PD activity, with deficient G6PD activity, and from confirmed heterozygous females would be of great value to both the development of tests for G6PD deficiency and to their early evaluation.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, exposure to heat en route to a central laboratory may affect the accuracy of biochemical G6PD testing. 47 Whom to screen? A second challenge is whether screening should be (i) targeted to high-risk groups or (ii) universal.…”
Section: Research Gapsmentioning
confidence: 99%
“…Loss in enzyme activity had previously been found to be quite significant in blood samples (albeit anticoagulated with EDTA) stored at room temperature, when after 15-day storage, G6PD levels fell by approximately 60% [16]. While storage-dependent changes in G6PD function have been described in leucoreduced donor blood units [17] additives such as that described by Kahn et al, [18] appeared to extend the functionality of intact red cells when analysed by flow cytometry, even though the overall G6PD level remained stable over a 21-day period.…”
Section: Discussionmentioning
confidence: 96%