2009
DOI: 10.1021/je800857x
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Gas Solubility Prediction in Ionic Liquids using COSMOthermX

Abstract: As the range of available ionic liquids increases, methods by which important engineering parameters such as gas solubilities can be estimated from simple structural information become ever more desirable. COSMO-based thermodynamic models, such as that used by COSMOthermX, allow the determination of such data for pure and mixed component systems. Herein, we evaluate the predictive capability of COSMOthermX through a comparison with literature data obtained from the IUPAC database which contains data for 15 gas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

7
92
1

Year Published

2012
2012
2018
2018

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 94 publications
(100 citation statements)
references
References 113 publications
7
92
1
Order By: Relevance
“…This solution has been addressed by several research groups in different application fields and using rather dissimilar strategies 7,[12][13][14][15][16][17][18][19] . In particular, our group has been worked 20 in the integration of the molecular modeling and the process simulation via the COSMO-based 21,22 In the last five years, we have successfully applied COSMO-based/Aspen Plus (Aspen HYSYS) procedure to the design and analysis of new different processes using ILs: absorption of toluene in packed/tray columns 30 , absorption refrigeration cycles 31 , aromatic-aliphatic separation by liquidliquid extraction 25,32,33 , extractive distillation 34 and CO 2 capture by physical absorption 9 .…”
Section: Introductionmentioning
confidence: 99%
“…This solution has been addressed by several research groups in different application fields and using rather dissimilar strategies 7,[12][13][14][15][16][17][18][19] . In particular, our group has been worked 20 in the integration of the molecular modeling and the process simulation via the COSMO-based 21,22 In the last five years, we have successfully applied COSMO-based/Aspen Plus (Aspen HYSYS) procedure to the design and analysis of new different processes using ILs: absorption of toluene in packed/tray columns 30 , absorption refrigeration cycles 31 , aromatic-aliphatic separation by liquidliquid extraction 25,32,33 , extractive distillation 34 and CO 2 capture by physical absorption 9 .…”
Section: Introductionmentioning
confidence: 99%
“…35,36 As demonstrated previously, an estimation of IL free volume can be straightforwardly acquired using the COSMO-RS (COnductor-like Screening MOdel for Real Solvents) computational method. 37 In short, the free volume is calculated as the difference between the molar volume (calculated using the ratio between the molecular weight and the density at 303 K predicted by the COSMOthermX software) and the COSMO volume of each IL.…”
Section: Methodsmentioning
confidence: 99%
“…These descriptors are calculated from quantum chemistry method known as COSMO (Conductor-like Screening Model). During this work, the same methodology as already presented by Ab Manan et al [39] was used to optimise each structure and to calculate the CO 2 solubility in selected solvents, as well as in solvents containing additive salts like LiPF 6 or [C 2 mim][NTf 2 ] ionic liquid where each reported binary composition describes the liquid phase used in the COSMOthermX software. As the calculation of the gas solubility by using COSMOThermX software (version 2.1, release 01.06) requires the prior knowledge of pure compound vapour pressures of pure components, these data were taken from the literature for the CO 2 [40] and also for each studied solvent [41][42][43][44][45][46].…”
Section: Predictive Methodsmentioning
confidence: 99%
“…As the calculation of the gas solubility by using COSMOThermX software (version 2.1, release 01.06) requires the prior knowledge of pure compound vapour pressures of pure components, these data were taken from the literature for the CO 2 [40] and also for each studied solvent [41][42][43][44][45][46]. Vapour pressures were also estimated by generating 'energy values' by using Turbomole program [47], as already described into the literature [39,48].…”
Section: Predictive Methodsmentioning
confidence: 99%
See 1 more Smart Citation