2014
DOI: 10.1002/elps.201400293
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of fritless solid‐phase extraction coupled on‐line with capillary electrophoresis‐mass spectrometry for the analysis of opioid peptides in cerebrospinal fluid

Abstract: Fritless SPE on-line coupled to CE with UV and MS detection (SPE-CE-UV and SPE-CE-MS) was evaluated for the analysis of opioid peptides. A microcartridge of 150 μm id was packed with a C18 sorbent (particle size > 50 μm), which was retained between a short inlet capillary and a separation capillary (50 μm id). Several experimental parameters were optimized by SPE-CE-UV using solutions of dynorphin A (DynA), endomorphin 1 (End1), and methionine-enkephaline (Met). A microcartridge length of 4 mm was selected, sa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
42
0

Year Published

2015
2015
2016
2016

Publication Types

Select...
5
1
1

Relationship

3
4

Authors

Journals

citations
Cited by 34 publications
(42 citation statements)
references
References 49 publications
(93 reference statements)
0
42
0
Order By: Relevance
“…Medina‐Casanellas et al. developed an in‐line SPE‐CE‐MS method for the determination of opioid peptides in human cerebrospinal fluid (CSF) . A microcartridge of 150 μm id was packed with a C18 sorbent (particle size >50 μm), which was retained without using frits between a short inlet capillary and a separation capillary (50 μm id).…”
Section: Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Medina‐Casanellas et al. developed an in‐line SPE‐CE‐MS method for the determination of opioid peptides in human cerebrospinal fluid (CSF) . A microcartridge of 150 μm id was packed with a C18 sorbent (particle size >50 μm), which was retained without using frits between a short inlet capillary and a separation capillary (50 μm id).…”
Section: Applicationsmentioning
confidence: 99%
“…Experimental conditions: sample loading, 10 min at 930 mbar; elution, 63 s at 50 mbar; separation voltage, 25 kV; EIEs: 434.7 (Dynorphin A (1‐7)), 611.2 (Endomorphin 1), and 574.2 (Met‐enkephalin). Reproduced with permission from .…”
Section: Applicationsmentioning
confidence: 99%
“…However, other authors have preferred the term “in‐line” because the microcartridge is fully integrated with the separation capillary . Both terms are actually coexisting in the literature, something that has generated some controversy . SPE‐CE‐MS has been extensively explored using the silica or polymeric sorbents typically used in off‐line SPE (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…SPE‐CE‐MS has been extensively explored using the silica or polymeric sorbents typically used in off‐line SPE (e.g. C18) , because of the versatility, the large active surface area, the compatibility with the on‐line electrophoretic separation and detection and the commercial availability at a reasonable price. However, the limited selectivity of such sorbents hinders very often the analysis of complex samples, such as biological fluids, even with MS detection .…”
Section: Introductionmentioning
confidence: 99%
“…A fritless SPE microcartridge of 150 μm id and 4 mm length packed with C18 sorbent (particle size >50 μm) and retained between a short inlet capillary and a separation capillary (50 μm id) was applied to analysis of opioid peptides (dynorphin, endomorphin 1, and Met‐enkephalin) in cerebrospinal fluid (CSF) , see Fig. .…”
Section: Sample Preparationmentioning
confidence: 99%