2006
DOI: 10.1021/ac051878h
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Flow Cell Detector Configurations Combining Simultaneous Preconcentration and Scintillation Detection for Monitoring of Pertechnetate in Aqueous Media

Abstract: Flow cell detectors were developed for simultaneous concentration and scintillation detection of technetium-99 in water. Evaluated flow cell geometries consisted of a coil and a fountain flow cell design; the latter is based on radial solution flow through a resin bed interfaced with a photomultiplier tube through a polycarbonate window. The sorptive scintillating media investigated were (1) an extractive scintillator combining a porous polystyrene resin with the extractant Aliquat-336 and fluor 2-(1-naphthyl)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(25 citation statements)
references
References 18 publications
(29 reference statements)
0
24
1
Order By: Relevance
“…Fig. 13 C NMR experimental spectra are given in ESI † (Fig. The figure confirms the successful organic synthesis of vNPO and allylNPO relative to the starting material (aNPO).…”
Section: Monomers Synthesis and Polymer Stabilitymentioning
confidence: 65%
See 3 more Smart Citations
“…Fig. 13 C NMR experimental spectra are given in ESI † (Fig. The figure confirms the successful organic synthesis of vNPO and allylNPO relative to the starting material (aNPO).…”
Section: Monomers Synthesis and Polymer Stabilitymentioning
confidence: 65%
“…All 1 H and 13 C NMR spectra were recorded on a JEOL ECX-300 spectrometer operating at 300 MHz for 1 H NMR and 75 MHz for 13 C NMR at room temperature and in CDCl 3 solvent. The chemical shifts (d) are reported in ppm and were referenced to the residual solvent peak.…”
Section: Instrumentationmentioning
confidence: 99%
See 2 more Smart Citations
“…The obtained eluates are diluted up to a volume of 2 mL with 22.5 % Aliquat®336 in acetone and mixed with 8 mL of liquid scintillation cocktail, according to the LSC manufacturer's recommendations [19]. Borosilicate glass LSC vials were kept in the dark overnight and measured the following day to avoid interferences due to fluorescence and/or phosphorescence [20].…”
Section: Analytical Proceduresmentioning
confidence: 99%