Evaluation of field impact sound pressure levels as a function of tapping machine location

Abstract: Field impact sound insulation in the United States is typically quantified in terms of field impact insulation class, which is defined in ASTM E1007. This standard requires averaging the receiving room impact sound pressure levels (ISPL) generated by the tapping machine in four defined positions. In a previous paper [LoVerde and Dong, J. Acoust. Soc. Am. 121, 3113 (2007)] the authors analyzed several hundred field tests to determine effects of reducing the number of tapping machine positions on the FIIC rating… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Direct comparison is not possible since a different set of tapping machine positions was used, but the concrete assembly, despite lacking a joist structure, has a similar range of variation as the wood joist floor. In our previous study [9], we also observed no systematic difference between wood joist and concrete floors. This implies that the variation is not attributable to the tapping machine being on or between the joists.…”
Section: Concrete Floormentioning
confidence: 39%
See 2 more Smart Citations
“…Direct comparison is not possible since a different set of tapping machine positions was used, but the concrete assembly, despite lacking a joist structure, has a similar range of variation as the wood joist floor. In our previous study [9], we also observed no systematic difference between wood joist and concrete floors. This implies that the variation is not attributable to the tapping machine being on or between the joists.…”
Section: Concrete Floormentioning
confidence: 39%
“…Using the ASTM standard tapping machine positions, two of the positions are directly above a joist and two are between the joists. The previous studies [9], [10] did not identify any systematic differences between the tapping machine positions. However, those studies did not examine the bands below 100 Hz, while Larsson et al observed this effect only below 100 Hz.…”
Section: Previous Studiesmentioning
confidence: 70%
See 1 more Smart Citation