Evaluation of Fatigue Crack Propagation in The Post-Service Gas Turbine Vane

Abstract: Local area fatigue crack propagation resistance of a retired gas turbine vane made of a Ni-based superalloy which had been operating for about 20000 h. in a 1100 °C level land-based gas turbine, was experimentally evaluated. Here, special efforts were made to build up a new testing apparatus to assess the fatigue crack propagation resistance, using the miniature size specimens extracted from the vane. The miniature specimens were extracted from the leading and the trailing edges, respectively. It was shown tha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
1
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 13 publications
0
1
0
Order By: Relevance
“…In this work the miniature compact tension (CT) specimens illustrated in Fig. 2 were extracted from the cast superalloy rods for the fatigue test [6]. The geometry of specimen was designed so that it was almost proportional to that recommended in ASTM E647 [8], except for the specimen thickness.…”
Section: Specimen Preparationmentioning
confidence: 99%
See 3 more Smart Citations
“…In this work the miniature compact tension (CT) specimens illustrated in Fig. 2 were extracted from the cast superalloy rods for the fatigue test [6]. The geometry of specimen was designed so that it was almost proportional to that recommended in ASTM E647 [8], except for the specimen thickness.…”
Section: Specimen Preparationmentioning
confidence: 99%
“…These loadings inevitably cause many types of damages and degradations in components during the operation period. Materials used in them, especially Ni-base superalloys, are so expensive items that they can be a substantial part of an operating and a maintenance budget [1][2][3][4][5][6][7]. Therefore, it is of considerable technical and financial benefit if the condition of the blades can be assessed and their remaining life determined.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Some reasons are responsible for following problems: i) Fatigue crack propagation (FCP) tests are usually carried out using standard size specimens (5-10mm thickness) [10], although actual crack growth takes place in thin wall components with cooling systems, where the wall thickness is about 0.5-1.0mm. The thickness dependency of crack propagation may lead to a discrepancy between the laboratory results and the actual crack growth [11]. ii) Little is known quantitatively about effects of both the crystal and grain boundary orientation [12,13].…”
Section: Introductionmentioning
confidence: 99%