2005
DOI: 10.1016/j.enggeo.2004.10.015
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of dynamic response and local soil effects of the Evripos cable-stayed bridge using multi-sensor monitoring systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
28
0
5

Year Published

2006
2006
2019
2019

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 58 publications
(37 citation statements)
references
References 8 publications
2
28
0
5
Order By: Relevance
“…Lekidis et al [28], in particular, identified modes of vibration at the range 0.37-0.54 Hz in a relatively small (middle span of 215 m) cable-stayed bridge in Greece, a result consistent with both FEM predictions and results of observations with a robotic total station. Their measurements were based on a system of two base receivers, and centimetre to sub-centimetre level accuracies were claimed.…”
Section: Major Suspension Bridgessupporting
confidence: 78%
See 2 more Smart Citations
“…Lekidis et al [28], in particular, identified modes of vibration at the range 0.37-0.54 Hz in a relatively small (middle span of 215 m) cable-stayed bridge in Greece, a result consistent with both FEM predictions and results of observations with a robotic total station. Their measurements were based on a system of two base receivers, and centimetre to sub-centimetre level accuracies were claimed.…”
Section: Major Suspension Bridgessupporting
confidence: 78%
“…In the second case, Celebi and Sanli [27] found a similarity in the estimates of the natural frequency of a building deduced from GPS recordings and an accelerometer record during an earthquake. Lekidis et al [28] also arrived at a similar conclusion on the basis of the comparison of the spectra of a suspended bridge derived from independent accelerometer, GPS and robotic total station data.…”
Section: Methods To Assess the Accuracy Of Gps Kinematic Techniquesmentioning
confidence: 79%
See 1 more Smart Citation
“…Li et al [33] presented a new and practical method for the deformation monitoring of the Yellow River Shengli Bridge by the integration of GPS and total station technology. Lekidis et al [34] studied the dynamic characteristics of the Evripos cable-stayed bridge using total station and GPS, and the results showed that whilst the robotic total station solutions yielded a precision of 2-3 mm for absolute height displacements, the GPS results indicated that the bridge deck was not well suited for high precision monitoring due to the shading and diffraction effects caused by the steel cables.…”
Section: Integrating Gps Receiver and Other Sensors To Monitor The Dementioning
confidence: 96%
“…However, the monitoring of soil-abutment interaction using vibration signals has been lacking. The detection and monitoring of soil-abutment contact pressures are critical for abutment design and maintenance management [3][4][5][6][7][8][9][10][11][12][13][14]. Investigations to examine the effect of the earth pressure conditions on vehicle-induced soilstructure interactions and to quantify the amplification and frequency content of the vibrations transmitted could be instrumental in assessing the dynamic characteristics of the related structures.…”
Section: Introductionmentioning
confidence: 99%