2008
DOI: 10.4103/0970-4388.44032
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of different sterilization and disinfection methods on commercially made preformed crowns

Abstract: The aim of this study was to evaluate the changes caused by different sterilization or disinfection methods on the vestibular surface of four commercially made preformed crowns using stereomicroscopy and scanning electron microscopy (SEM). Preformed crowns (NuSmile Primary Anterior Crown (NSC), Kinder Krowns (KK), Pedo Pearls (PP) and polycarbonate crowns (PC)) were sterilized and/or disinfected by one of the following techniques: no sterilization or disinfection (G1 control group); steam autoclaving at 134 de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
18
0
2

Year Published

2012
2012
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(26 citation statements)
references
References 10 publications
1
18
0
2
Order By: Relevance
“…If necessary, they can be covered with composite [ 62 ]. Their disadvantages are their soft structure and possible shorter durability [ 63 ].…”
Section: Crownsmentioning
confidence: 99%
“…If necessary, they can be covered with composite [ 62 ]. Their disadvantages are their soft structure and possible shorter durability [ 63 ].…”
Section: Crownsmentioning
confidence: 99%
“…However, the coating tends to chip off in areas of heavy occlusion and in bruxers that can be easily repaired with composite. 2,4,6,10,19…”
Section: Pedo Pearlsmentioning
confidence: 99%
“…Chemical disinfection or cold sterilization using an aldehyde-free disinfectant in an ultrasonic bath. 19,20,32 Preferred method for PVSSC, High density polyethylene veneered crowns, Polycarbonate crowns, Pedo Pearls and Pedo jacket crowns 2. Steam Autoclave SSCs, Zirconia crowns, Figaro crowns…”
Section: Edelweiss Pediatric Crownsmentioning
confidence: 99%
“…Debido a que en los dos procesos de esterilización por calor húmedo (121°C) y calor seco (140°C), se superan las temperaturas de transición vítrea y aumenta su CTE, existe la posibilidad de que las dimensionen del material se mantengan modificadas después del proceso de enfriado, ya que físicamente no se encontraron cambios dimensionales en las probetas luego de los procesos de esterilización. En otros estudios sobre policarbonato esterilizado a diferentes temperaturas, sobre 121°C por calor húmedo para coronas dentales estéticas, no se observaron cambios superficiales al realizar la revisión por estereomicroscopio a 60X, pero a través de micrografías por SEM se ha observado grietas y alteración del contorno de las coronas, estas grietas se produjeron por la presencia de las microfibras de vidrio en el compuesto y debido a que la esterilización se llevó a cabo a 134°C, siendo el punto de distorsión por calor de las coronas de 132.2°C, también se observaron cambios superficiales con la esterilización por calor húmedo a 121°C, similar a esta investigación, pero con un tiempo de exposición de 30 minutos [436].…”
Section: Launclassified