2020
DOI: 10.1109/tpel.2019.2962907
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Different Si/SiC Hybrid Three-Level Active NPC Inverters for High Power Density

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
26
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 66 publications
(27 citation statements)
references
References 30 publications
1
26
0
Order By: Relevance
“…As far as the price of SiC devices is concerned, if all six switching devices in the ANPC topology are replaced with SiC devices, the high cost will limit the widespread application of such products. Considering this problem, many studies have proposed hybrid applications of SiC and silicon (Si) devices, that is, only some of the devices in a system or topology are replaced with SiC devices [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19]. In [5], a Si CSI (current source inverter)/SiC VSI (voltage source inverter) series inverter system was proposed.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…As far as the price of SiC devices is concerned, if all six switching devices in the ANPC topology are replaced with SiC devices, the high cost will limit the widespread application of such products. Considering this problem, many studies have proposed hybrid applications of SiC and silicon (Si) devices, that is, only some of the devices in a system or topology are replaced with SiC devices [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19]. In [5], a Si CSI (current source inverter)/SiC VSI (voltage source inverter) series inverter system was proposed.…”
Section: Introductionmentioning
confidence: 99%
“…This hybrid topology can increase efficiency by 66%. In addition, based on the diversity of ANPC topology commutation modes, various hybrid SiC and Si configuration schemes have also been proposed [8][9][10][11][12][13][14][15][16][17][18][19]. In [8][9][10][11], the outer tubes connected to the bus and clamp tubes in the ANPC topology were replaced by SiC devices.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…That is, when the fault-phase voltage is offset to this range, the fault point can not arcing, and the ground fault is effectively suppressed. Additionally, according to different application scenarios, the topology structure of the active inverter can be single-phase H-bridge, cascaded H-bridge, modular multilevel converter (MMC), and multi-material devices [ 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 ]. In order to achieve the high voltage output of the active inverter, the multilevel topology or cascaded H-bridge can be adopted [ 44 , 45 , 46 , 47 , 48 , 49 ].…”
Section: Introductionmentioning
confidence: 99%