1987
DOI: 10.1016/0167-7322(87)80036-3
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of complex permittivity of aqueous solution by time domain reflectometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
50
0

Year Published

1990
1990
2015
2015

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 84 publications
(51 citation statements)
references
References 20 publications
1
50
0
Order By: Relevance
“…Dielectric measurements in the frequency range of 1 kHz to 20 GHz were performed following the TDR method (Cole et aL, 1980;Mashimo et al, 1987a). In this method, a step-voltage pulse, with a 30-ps rise time and 200-mV height, generated by a tunnel diode passes through a flexible coaxial cable (Suhner Electrics, Ltd., Sucoform 141PE, 50 gl, dc: 26.5 GHz) to the sample surface upon which the applied pulse is reflected.…”
Section: Tdr Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Dielectric measurements in the frequency range of 1 kHz to 20 GHz were performed following the TDR method (Cole et aL, 1980;Mashimo et al, 1987a). In this method, a step-voltage pulse, with a 30-ps rise time and 200-mV height, generated by a tunnel diode passes through a flexible coaxial cable (Suhner Electrics, Ltd., Sucoform 141PE, 50 gl, dc: 26.5 GHz) to the sample surface upon which the applied pulse is reflected.…”
Section: Tdr Methodsmentioning
confidence: 99%
“…Hence, the contribution of dc conductivity to the complex permittivity must be precisely evaluated, especially in the low-frequency range. This evaluation is possible using a reference TDR method (Cole et al, 1980;Mashimo et al, 1987a). If a standard sample with known permittivity is employed as a reference and the conductivity is adjusted to be approximately the same as that of an unknown sample, the complex permittivity of the unknown sample can be obtained as a function of the ratio of the Fourier transforms of the two reflected waves from the known and the unknown samples, respectively.…”
Section: Introductionmentioning
confidence: 99%
“…TDR measuring system equipped a sampling head (HewlettPackard 54121 A) and a mainframe of digitizing oscilloscope (Hewlett-Packard 54121B), covered the frequency range from 10 MHz to 20 GHz. Details of TDR were described in former literatures [5,[11][12][13]. IMA (Hewlett-Packard 4291A) and LCR meter (Hewlett-Packard 4284A) was utilized to cover the range of 1 MHz-1.8 GHz and 20 Hz-1 MHz, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…A detailed description of this method is presented elsewhere (12). An incident pulse with a rise time of 30 ps generated by a pulse generator passes through a 50 ⍀ coaxial cable and is reflected from the top of the cable, where the sample cell is attached.…”
Section: Complex Permittivitymentioning
confidence: 99%