2014
DOI: 10.1016/j.eurpolymj.2014.07.005
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of chemical kinetics in positive photoresists using laser desorption ionization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 19 publications
0
3
0
Order By: Relevance
“…Second, this technique identified the m/z 304.24 peak related to the AA in both non-stimulated and AA-stimulated samples. In order to verify the existence of a fluctuation at the m/z 304.24 peak of the non-stimulated and AA-stimulated sample, the yield related to this peak was calculated by dividing the peak area by the total area of the corresponding spectrum, as before [ 48 ]. Thus, m/z 304.24 peak from the non-stimulated and AA-stimulated samples showed a related yield of 0.0035 and 0.018 respectively, that is, 5 times higher in the stimulated group ( Fig 5B , black line) compared to the value obtained from the non-stimulated sample ( Fig 5B , red line).…”
Section: Resultsmentioning
confidence: 99%
“…Second, this technique identified the m/z 304.24 peak related to the AA in both non-stimulated and AA-stimulated samples. In order to verify the existence of a fluctuation at the m/z 304.24 peak of the non-stimulated and AA-stimulated sample, the yield related to this peak was calculated by dividing the peak area by the total area of the corresponding spectrum, as before [ 48 ]. Thus, m/z 304.24 peak from the non-stimulated and AA-stimulated samples showed a related yield of 0.0035 and 0.018 respectively, that is, 5 times higher in the stimulated group ( Fig 5B , black line) compared to the value obtained from the non-stimulated sample ( Fig 5B , red line).…”
Section: Resultsmentioning
confidence: 99%
“…The time-of-flight mass spectrometer consists basically of an electrostatic ion extraction system, a collimating electrostatic lens, a drift tube, an electrostatic mirror and a pair of microchannel plate (MCP) detectors, disposed in the chevron configuration (refletron detector) [20]. After extraction, ionic molecular fragments travel through the flight tube until reaching the MCP.…”
Section: Methodsmentioning
confidence: 99%
“…Matrix-assisted laser desorption/ionization timeof-flight mass spectrometry (MALDI-TOF MS) [1,2] has, as main characteristics, the easy sample production, soft ionization, easy operation, fast analysis and high accuracy. Mass spectrometry MALDI has been widely used in analyses of large molecules such as proteins [3], peptides [4], polysaccharides [5], oligonucleotides [6], Polymer [7,8], and DNA [9].…”
Section: Introductionmentioning
confidence: 99%