Evaluation of Biological Air Filters for Livestock Ventilation Air by Membrane Inlet Mass Spectrometry

Abstract: Biological air filters have been proposed as a cost-effective technology for reducing odor emissions from intensive swine production facilities. In this work we present results from the application of membrane inlet mass spectrometry (MIMS) for continuously monitoring the removal of odorous compounds in biological air filters. The sensitivity and selectivity were tested on synthetic samples of selected odorous compounds, and linearity and detection limits in the lower ppb range were demonstrated for all compou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

4
44
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 45 publications
(48 citation statements)
references
References 49 publications
4
44
0
Order By: Relevance
“…The pig stable-air emission and removal efficiencies of each biofilter compartment were analyzed by using thermal desorption gas chromatography-mass spectrometry (TD-GC/MS) and membrane inlet mass spectrometry (MIMS; QMG 422; Balzers, Liechtenstein) according to a previously developed method (11). Briefly, insulated polyterafluoroethylene tubes of equal length were installed in (i) the ventilation channel before the biofilter, (ii) between the two filter sections, and (iii) after the filter used for air sampling.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The pig stable-air emission and removal efficiencies of each biofilter compartment were analyzed by using thermal desorption gas chromatography-mass spectrometry (TD-GC/MS) and membrane inlet mass spectrometry (MIMS; QMG 422; Balzers, Liechtenstein) according to a previously developed method (11). Briefly, insulated polyterafluoroethylene tubes of equal length were installed in (i) the ventilation channel before the biofilter, (ii) between the two filter sections, and (iii) after the filter used for air sampling.…”
Section: Methodsmentioning
confidence: 99%
“…The custom-built membrane inlet (Mikrolab, Denmark) was holding a poly-(dimethylsiloxane) sheet membrane (130 m thickness; Technical Products, Lawrenceville, GA). The inlet temperature was held at 50°C, and the sample flow over the membrane was 300 ml min Measurement of dimethyl disulfide in the Randers filter was conducted together with the analysis of methanethiol, dimethyl sulfide, and H 2 S by proton transfer reaction mass spectrometry (PTR-MS) analysis at a single time point (11). Briefly, 5 liters of air were collected in nalophan bags and transported directly to the laboratory.…”
Section: Methodsmentioning
confidence: 99%