1976
DOI: 10.1136/jcp.29.4.317
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of automated large-scale screening tests for syphilis.

Abstract: Previous authors (Pugh and Gaze, 1966;Wagstaff et al, 1969) have reported favourably on the use of the Technicon AutoAnalyzer for automation of the CWR and RPCFT, but one of the main problems seemed to be the continuous flow system's limited rate of testing. If all specimens were tested against cardiolipin and Reiter antigens separately, and all those giving positive or doubtful results were retested against complement alone, it would be difficult to test more than 150 samples each day as allowance must be mad… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

1977
1977
2019
2019

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 6 publications
(5 reference statements)
1
3
0
Order By: Relevance
“…In the comparisons summarised in Tables 2 and 3, the TPHA was slightly more sensitive than the ARPCFT, and the most sensitive combination of tests was the ART and TPHA, although the difference was marginal in the case of the Fuzizoki TPHA. Somewhat surprisingly, the most specific test in all three comparisons was the ART, with a total of 69 positives and no false negatives, thus confirming our earlier observations on this test (Macfarlane et al, 1976). The false positive rate for the Wellcome TPHA 1:40 was 13 5% (five out of 37), and for the Fuzizoki TPHA 10 8 % (four out of 37), but the Wellcome TPHA 1:40 recorded a lower false negative rate of 0-16% compared with 0-32% for the Fuzizoki TPHA.…”
Section: Discussionsupporting
confidence: 88%
See 1 more Smart Citation
“…In the comparisons summarised in Tables 2 and 3, the TPHA was slightly more sensitive than the ARPCFT, and the most sensitive combination of tests was the ART and TPHA, although the difference was marginal in the case of the Fuzizoki TPHA. Somewhat surprisingly, the most specific test in all three comparisons was the ART, with a total of 69 positives and no false negatives, thus confirming our earlier observations on this test (Macfarlane et al, 1976). The false positive rate for the Wellcome TPHA 1:40 was 13 5% (five out of 37), and for the Fuzizoki TPHA 10 8 % (four out of 37), but the Wellcome TPHA 1:40 recorded a lower false negative rate of 0-16% compared with 0-32% for the Fuzizoki TPHA.…”
Section: Discussionsupporting
confidence: 88%
“…The method used for the automated tests described by Macfarlane et al (1976) was slightly modified. The complement titration was performed using a weak positive serum and the end point was selected to give a predetermined reading with this serum.…”
Section: Introductionmentioning
confidence: 99%
“…It is difficult for clinicians to assess the biological significance of the serofast state (15). Although nontreponemal tests, such as the toluidine red unheated serum test, the rapid plasma reagin serological test and the venereal disease research laboratory slide test, are able to measure IgG and IgM antibodies to TP and potentially to cardiolipin and lipoidal material released from damaged host cells during syphilis infection, other illnesses that produce tissue damage may also lead to positive results (16). In clinical practice, it is a challenge to manage patients with syphilis at the serofast stage using the recommended treatments.…”
Section: Discussionmentioning
confidence: 99%
“…The automated tests were performed according to methods previously described (MacFarlane et al, 1976).…”
Section: Methodsmentioning
confidence: 99%