2008
DOI: 10.3343/kjlm.2008.28.6.475
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Automated Architect Syphilis TP as a Diagnostic Laboratory Screening Test for Syphilis

Abstract: Background : The aim of the study was to establish a new syphilis test algorithm using Architect Syphilis TP (Abbott Japan, Japan: AST), a fully automated treponemal antibody test, as a screening test in a university hospital laboratory. We evaluated performance characteristics of AST in various patient groups.Methods : A total of 1,357 serum samples obtained from patients at a university hospital from June to August, 2008 were categorized into checkup, preoperative, other diseases, diagnosis (clinically suspe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
2
0

Year Published

2009
2009
2017
2017

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 7 publications
1
2
0
Order By: Relevance
“…In conclusion, the Elecsys syphilis assay displays better sensitivity (100%), specificity (99.8%), PPV (98.7%), and NPV (100%) in 2,124 samples enrolled, compared with the InTec assay. The Elecsys ® Syphilis assay perfectly agreed with the InTec ELISA test kit and was also compared favorably with or better than other CLIAs reported in the literature . Besides, the Elecsys ® Syphilis assay demonstrates more priority in the terms of ease of use, high sensitivity in early syphilis, and less sera.…”
Section: Discussionsupporting
confidence: 59%
“…In conclusion, the Elecsys syphilis assay displays better sensitivity (100%), specificity (99.8%), PPV (98.7%), and NPV (100%) in 2,124 samples enrolled, compared with the InTec assay. The Elecsys ® Syphilis assay perfectly agreed with the InTec ELISA test kit and was also compared favorably with or better than other CLIAs reported in the literature . Besides, the Elecsys ® Syphilis assay demonstrates more priority in the terms of ease of use, high sensitivity in early syphilis, and less sera.…”
Section: Discussionsupporting
confidence: 59%
“…Architect syphilis TP assay has been known to have an excellent sensitivity and specificity [11, 12]. In our study, from the RSSS using the Architect Syphilis TP CIA as a screening assay, the positive rate of CIA was 1.7% in our low-prevalence population, and the proportion of TP-PA-negative sera among 153 CIA-reactive sera was 10.5% (16/153).…”
Section: Discussionmentioning
confidence: 60%
“…This may be related to increased incidence of HIV infection: cases of coinfection with syphilis and HIV have been reported in Korea. Therefore, syphilis may become a more common clinical challenge [10]. …”
Section: Discussionmentioning
confidence: 99%