1998
DOI: 10.1002/(sici)1096-9888(199811)33:11<1109::aid-jms728>3.0.co;2-1
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of adsorption preconcentration/capillary zone electrophoresis/nanoelectrospray mass spectrometry for peptide and glycoprotein analyses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
18
0

Year Published

1999
1999
2005
2005

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 52 publications
(19 citation statements)
references
References 6 publications
1
18
0
Order By: Relevance
“…This is presumably due to incomplete desorption of analytes using a relatively low volume of organic buffer (25 nL) to minimize loss of separation performance [36]. Adsorptive preconcentration favored the enrichment of hydrophobic peptides whereas sample stacking provided significant enhancement of sensitivity for hydrophilic peptides of high electrophoretic mobilities.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This is presumably due to incomplete desorption of analytes using a relatively low volume of organic buffer (25 nL) to minimize loss of separation performance [36]. Adsorptive preconcentration favored the enrichment of hydrophobic peptides whereas sample stacking provided significant enhancement of sensitivity for hydrophilic peptides of high electrophoretic mobilities.…”
Section: Discussionmentioning
confidence: 99%
“…Previous investigations have described the application of SPE to selectively enrich proteolytic fragments prior to CE/ nES-MS analyses [33,36]. Previous investigations have described the application of SPE to selectively enrich proteolytic fragments prior to CE/ nES-MS analyses [33,36].…”
Section: Spe Coupled To the Chip Ce/nes-msmentioning
confidence: 99%
“…Different approaches of on-line SPE preconcentration in the CE capillary, e.g., [63] have been developed. The SPE-CE-MS approach has especially been applied in the context of peptide analysis [33,[64][65][66]. The usefulness of online SPE-CE-MS for quantitative measurements has been shown by Waterval et al [67].…”
Section: Coating and Preconcentrationmentioning
confidence: 99%
“…To improve sensitivity, more or less simple on-line enrichment can be applied [15][16][17][18]. Not only off-line but also on-capillary preconcentration by a stationary phase like C18-material on particles or absorbed on a membrane can be performed since CZE is very tolerant with respect to organic solvents [21][22][23]. Several groups (e.g., [19,20]) used transient-ITP to preconcentrate peptides at least by a factor of 10.…”
Section: Introductionmentioning
confidence: 99%