Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2014
DOI: 10.1186/1471-2334-14-187
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on contamination levels of methicillin-resistant Staphylococcus aureus

Abstract: BackgroundHealthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional health care costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study was to compare standard manual room-cleaning to PPX-UV disinfection technology for MRSA and bacterial heterotrophic plate counts (HPC) on high-tou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

3
78
0
3

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 80 publications
(84 citation statements)
references
References 22 publications
3
78
0
3
Order By: Relevance
“…4,9 The finding that interrupted and uninterrupted UV-C exposures were similarly effective suggests that the practice of running 2 cycles in different locations in the room will not adversely affect performance. [11][12] Finally, positioning of objects such as call buttons or tables in close proximity to UV-C devices has been recommended to take advantage of the fact that efficacy is reduced as distance from the device increases. [3][4][5][6][7][8] Our results suggest that orientation of objects such that the largest surface area is in parallel with the UV-C lamps may enhance efficacy.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…4,9 The finding that interrupted and uninterrupted UV-C exposures were similarly effective suggests that the practice of running 2 cycles in different locations in the room will not adversely affect performance. [11][12] Finally, positioning of objects such as call buttons or tables in close proximity to UV-C devices has been recommended to take advantage of the fact that efficacy is reduced as distance from the device increases. [3][4][5][6][7][8] Our results suggest that orientation of objects such that the largest surface area is in parallel with the UV-C lamps may enhance efficacy.…”
Section: Discussionmentioning
confidence: 99%
“…[2][3][4][5][6][7][8][9][10] In hospital rooms, use of the devices has been shown to reduce the burden of pathogens on surfaces. [2][3][4][6][7][8][11][12][13] There have also been some reports of use of UV-C devices associated with reductions in healthcare-associated infections. [14][15][16] In addition to factors such as cost and ease of use, healthcare facilities considering the purchase of a UV-C room decontamination device must weigh claims regarding the effectiveness of different devices.…”
mentioning
confidence: 99%
“…8,11 In addition, our study provides 2 assessments not included in previous publications on PX-UV (ie, log reductions achieved by PX-UV on carriers and a comparison with continuous UV). Although the log reductions achieved by PX-UV on carriers at 10 minutes were relatively modest, this exposure time was sufficient to reduce contamination on real-world surfaces.…”
Section: Discussionmentioning
confidence: 99%
“…[1][2][3][4][5][6][7] Mercury gas bulbs primarily emit UV-C at 254 nm, whereas xenon gas bulbs produce a broad spectrum of radiation that encompasses the UV (100-280 nm) and visible (380-700 nm) spectra. [8][9][10][11][12] The UV-C radiation emitted by low pressure mercury bulbs is delivered in a continuous stream that gradually accumulates to lethal doses depending on duration of exposure and distance from the primary field of radiation. [1][2][3][4][5][6][7] The broad-range UV delivered by xenon bulbs is emitted in short, high-intensity pulses, possibly requiring a shorter duration of exposure to achieve lethal doses.…”
mentioning
confidence: 99%
See 1 more Smart Citation