2016
DOI: 10.2116/analsci.32.35
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a Portable Microchip Electrophoresis Fluorescence Detection System for the Analysis of Amino Acid Neurotransmitters in Brain Dialysis Samples

Abstract: A portable fluorescence detection system for use with microchip electrophoresis was developed and compared to a benchtop system. Using this system, six neuroactive amines commonly found in brain dialysate—arginine, citrulline, taurine, histamine, glutamate, and aspartate—were derivatized offline with naphthalene-2,3-dicarboxaldehyde/cyanide, separated electrophoretically, and detected by fluorescence. Limits of detection for the analytes of interest were 50nM – 250nM for the benchtop system and 250 nM – 1.3 μM… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 30 publications
0
13
0
Order By: Relevance
“…A separation of carnosine from the most abundant amino acids reported to be in macrophage cells was developed using standards. 24 The separation employed an all-glass 15-cm glass microchip with a BGE of 20 mM sodium borate (pH 9.2) and a field strength of 420 V/cm. None of the abundant amino acids co-migrated with carnosine under these optimal separation conditions (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…A separation of carnosine from the most abundant amino acids reported to be in macrophage cells was developed using standards. 24 The separation employed an all-glass 15-cm glass microchip with a BGE of 20 mM sodium borate (pH 9.2) and a field strength of 420 V/cm. None of the abundant amino acids co-migrated with carnosine under these optimal separation conditions (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…24 Briefly, a 445-nm PhoxX diode laser (Market Tech, Scotts Valley, CA, USA) was coupled to an Eclipse Ti-U inverted microscope (Nikon Instruments Inc., Melville, NY, USA) via a fiber optics cable. As CBI derivatives have an emission maximum of 490 nm, 23 the emission light was filtered through a long-pass edge filter with a 480 nm cutoff before being focused onto a photomultiplier tube (Hammatsu Corporation, Bridgewater, NJ, USA).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The initial report of this portable system compared it to a traditional benchtop system for the offline analysis of NDA/CN -derivatized amino acid neurotransmitters in rat brain microdialysate samples. While the port able system does suffer from higher limits of detection and quantitation than the benchtop system, it was still possible to detect basal levels of six amino acids in brain microdialysate in under 250 seconds (Figure 1.11B) (Oborny et al, 2016). Efforts are ongoing to couple this separation and detection scheme to previously reported online microdialysis sampling and derivatization (Nandi et al, 2013).…”
Section: Clinical Systems Employing Separation-based Sensorsmentioning
confidence: 94%
“…Currently, this system employs microdialysismicrochip electrophoresis with light emitting diodeinduced fluorescence detection (Oborny et al, 2016). As discussed in Section 1.4.3, microchip electrophoresis enables the fast separation of small volume samples on a microchip platform, which makes it amenable to clinical analysis.…”
Section: Clinical Systems Employing Separation-based Sensorsmentioning
confidence: 99%