2001
DOI: 10.2135/cropsci2001.4141351x
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a ninhydrin procedure for measuring membrane thermostability of wheat

Abstract: Membrane thermostability (MT) is used widely to measure high‐temperature tolerance of wheat (Triticum aestivum L.). However, the method, which measures conductivity of electrolytes released from injured cells, is affected by environmental factors for growing plants and is not effective on maturing plants. Amino acids exosmose like inorganic electrolytes from cells that are damaged by high temperature but, unlike electrolytes, typically occur only in living cells. These studies determined whether measuring leak… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 13 publications
(27 reference statements)
0
4
0
Order By: Relevance
“…The percentage of electrolyte leakage was calculated by using the formulae; MP (%) = ( C 1 / C 2 ) × 100 , where C 1 and C 2 are the electrolyte conductivities measured before and after boiling, respectively [11]. Briefly, a portion of fresh leaf material was weighed into a glass beaker containing reverse osmosis water.…”
Section: Methodsmentioning
confidence: 99%
“…The percentage of electrolyte leakage was calculated by using the formulae; MP (%) = ( C 1 / C 2 ) × 100 , where C 1 and C 2 are the electrolyte conductivities measured before and after boiling, respectively [11]. Briefly, a portion of fresh leaf material was weighed into a glass beaker containing reverse osmosis water.…”
Section: Methodsmentioning
confidence: 99%
“…Membrane stability index was determined in terms of percentage of electrolyte leakage (Cekic et al 2001) and lipid peroxidation level was measured in terms of malondialdehyde (MDA) content (Hodges et al 1999). Hydrogen peroxide estimation was done as per the protocol of Mukherjee and Choudhary (1983).…”
Section: Biochemical and Antioxidant Enzyme Assessmentmentioning
confidence: 99%
“…Calculation of the cholesterol levels was performed by dividing the OD value of an unknown sample with the OD value of the calibrator and then by multiplying by a factor of 4.6 (concentration of the calibrator in mg 100 ml -1 ). The free proline and total amino acids were measured with ninhydrin solution (0.70 mol l −1 NaH 2 PO 4 , 0.30 mol l −1 Na 2 HPO 4 , 0.03 mol l −1 ninhydrin and 0.02 mol l −1 fructose) according to Cekic and Paulsen (2001) and Rosen (1957). A 0.2 ml sample, 0.8 ml deionized water and 1.0 ml ninhydrin solution were mixed in a Pyrex tube and heated in boiling water for 10 min.…”
Section: Biochemical Assays For Cholesterol Free Amino Acids and Promentioning
confidence: 99%