2006
DOI: 10.1088/0031-9155/51/10/n01
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a new electromagnetic tracking system using a standardized assessment protocol

Abstract: This note uses a published protocol to evaluate a newly released 6 degrees of freedom electromagnetic tracking system (Aurora, Northern Digital Inc.). A practice for performance monitoring over time is also proposed. The protocol uses a machined base plate to measure relative error in position and orientation as well as the influence of metallic objects in the operating volume. Positional jitter (E(RMS)) was found to be 0.17 mm +/- 0.19 mm. A relative positional error of 0.25 mm +/- 0.22 mm at 50 mm offsets an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
57
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 82 publications
(60 citation statements)
references
References 7 publications
3
57
0
Order By: Relevance
“…Many studies assessing EM tracking systems for CAI can be found in the literature, e.g., [3,6,7,15,19,25,36,39,45,51,59,60,61,66,74,82,83,86,89,102,120,122,152,154,159,165,169,170,172,196,202,206,207]. However, in many cases, the results of these studies are not comparable because different measurement protocols and evaluation methods were used.…”
Section: B Study Resultsmentioning
confidence: 99%
“…Many studies assessing EM tracking systems for CAI can be found in the literature, e.g., [3,6,7,15,19,25,36,39,45,51,59,60,61,66,74,82,83,86,89,102,120,122,152,154,159,165,169,170,172,196,202,206,207]. However, in many cases, the results of these studies are not comparable because different measurement protocols and evaluation methods were used.…”
Section: B Study Resultsmentioning
confidence: 99%
“…22 The electromagnetic navigation system has a narrower measurement region, and errors can be generated by metal instruments such as stainless steel surgical instruments. 23 Image errors are dependent upon the image modes and are related to the sensor matrix size, slice thickness, voxel size, volume acquisition, signal-to-noise ratio, contrast, background structures, image distortion and software errors. 24 MRI has problems of motion artefacts and geometric inaccuracy because it has a longer scanning time, lower resolution and contrast, and limited visibility to bone tissue than CT. Cone beam CT has a smaller scan field (only 15-20cm) than multislice CT (MSCT), and is more accurate in the central region of the image.…”
Section: Discussionmentioning
confidence: 99%
“…Electromagnetic navigation may provide similar accuracy but are distorted by external magnetic fields and metal objects, leading to incorrect position sensing of up to 4 mm (71)(72)(73).…”
Section: Discussionmentioning