2018
DOI: 10.1111/ijlh.12869
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a new commercial method for von Willebrand factor multimeric analysis

Abstract: The commercial multimer method is a streamlined test that demonstrates comparable performance characteristics to our current laboratory-developed method and that provides the advantage of both electrophoresis gels and densitometry scans to aid interpretation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
25
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(28 citation statements)
references
References 20 publications
(81 reference statements)
1
25
0
1
Order By: Relevance
“…The Hydrasys VWF multimer system has undergone additional evaluation by our laboratory and several other groups 18–24 . Results in general reflect positively for the methodology, albeit with already‐noted limitations 18,20 .…”
Section: Vwd Type Classification Description Vwf:ag Vwf:gpib Bindinga Vwf:cb Fviii:c Multimers Gpib Binding/agb Cb/agb Fviii/vwfb Commentmentioning
confidence: 81%
“…The Hydrasys VWF multimer system has undergone additional evaluation by our laboratory and several other groups 18–24 . Results in general reflect positively for the methodology, albeit with already‐noted limitations 18,20 .…”
Section: Vwd Type Classification Description Vwf:ag Vwf:gpib Bindinga Vwf:cb Fviii:c Multimers Gpib Binding/agb Cb/agb Fviii/vwfb Commentmentioning
confidence: 81%
“…On the other hand, Bowyer et al 17 and a recent report by Favaloro et al 39 published quantitative HMWM loss in some of the type 2M patients. However, Crist et al 18 and Pikta et al 19 do not mention type 2M VWD in their studies about H5/11VWM.…”
Section: Discussionmentioning
confidence: 94%
“…We have previously reported on this multimer assay from the perspective of methodology validation, primarily via visual inspection of multimer patterns, but had not reported quantitative multimer separation vs quantitative VWF data. There have been few other reports on this method in the literature . Although some assessed multimer quantification according to manufacturer recommended groupings, none assessed this numerically in comparison with VWF activity/Ag ratios (as per our study), and none had assessed the chemiluminescence VWF procedures.…”
Section: Discussionmentioning
confidence: 96%
“…). Other workers using in house multimer systems use different separation approaches, for example the first five bands as LMWM, followed by bands 6‐10 as IMWM, and then finally bands >10 as HMWM.…”
Section: Discussionmentioning
confidence: 99%