Evaluation of a New Approach for Modeling Full Ring Stent Bundles with the Inclusion of Manufacturing Strains

Abstract: Ring stent bundles have been used in several biomedical stent-graft devices for decades, yet in the published literature, the numerical models of these structures always present significant simplifications. In this paper, a finite element (FE) ring stent bundle has been developed and evaluated with a combination of beam and surface elements. With this approach, the shape, the global stiffness and the strains of the structure can all be well predicted at a low computational cost while the approach is suitable f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 21 publications
(24 reference statements)
0
2
0
Order By: Relevance
“…A FEA stent model was assembled, compacted and deployed in each vascular section, and mechanical assessment followed. The FEA stent model used had been previously developed and validated 33 ; it is a ring stent bundle model, typical of the Scientific RepoRtS | (2020) 10:4673 | https://doi.org/10.1038/s41598-020-61578-y www.nature.com/scientificreports www.nature.com/scientificreports/ structural units found in the Anaconda TM endograft. In brief, it consists of a series of straight overlapping Nitinol wires that curve into a ring shape, to take into account the strains induced by the manufacturing process.…”
Section: Ellipses Circlesmentioning
confidence: 99%
“…A FEA stent model was assembled, compacted and deployed in each vascular section, and mechanical assessment followed. The FEA stent model used had been previously developed and validated 33 ; it is a ring stent bundle model, typical of the Scientific RepoRtS | (2020) 10:4673 | https://doi.org/10.1038/s41598-020-61578-y www.nature.com/scientificreports www.nature.com/scientificreports/ structural units found in the Anaconda TM endograft. In brief, it consists of a series of straight overlapping Nitinol wires that curve into a ring shape, to take into account the strains induced by the manufacturing process.…”
Section: Ellipses Circlesmentioning
confidence: 99%
“…A computationally efficient structural model of the ring stent bundles was achieved by representing the geometry and stiffness characteristics separately, similarly with a work developed earlier within our group. 15 More specifically, circular ring bundles were constructed using beam elements (B32, 3-node quadratic beam), enclosed by surface elements (SFM3D4R, 4-node quadrilateral surface element, reduced integration) as shown in Fig. 1 b.…”
Section: Methodsmentioning
confidence: 99%