Evaluation of a new air displacement plethysmograph for measuring human body composition

Abstract: PURPOSE: The Bod Pod uses air-displacement plethysmography to estimate body fat percentage (BF%). This study was designed to assess the test-retest reliability of the Bod Pod. METHODOLOGY: The study included 283 women (M age = 41.0 yr., SD = 3.0). Each participant was tested at least twice in the Bod Pod. Results showed no significant mean difference between the test and the retest. The intraclass correlation coefficient (ICC) was .991. However, the absolute value of the initial trial differences (absolute mea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

16
356
8
10

Year Published

2000
2000
2022
2022

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 433 publications
(394 citation statements)
references
References 0 publications
16
356
8
10
Order By: Relevance
“…24 The BodPod was calibrated daily according to the manufacturer's guidelines. Subjects wore clothing according to the manufacturer's Physical activity and body composition D Moliner-Urdiales et al recommendation (a swimsuit and a swim cap) to rule out air trapped in clothes and hair.…”
Section: Subjectsmentioning
confidence: 99%
See 1 more Smart Citation
“…24 The BodPod was calibrated daily according to the manufacturer's guidelines. Subjects wore clothing according to the manufacturer's Physical activity and body composition D Moliner-Urdiales et al recommendation (a swimsuit and a swim cap) to rule out air trapped in clothes and hair.…”
Section: Subjectsmentioning
confidence: 99%
“…25 Thoracic gas volume was measured following the manufacturer's recommendations. 24 This value was integrated into the calculation of body volume. Total body fat mass was calculated as percentage total body fat mass multiplied by body mass (kg) and then divided by 100.…”
Section: Subjectsmentioning
confidence: 99%
“…(Life Measurement Incorporated, Concord, CA, USA) according to the manufacturer's testing recommendations and guidelines. Details regarding the physical concepts and operational principles of the ADP are reported elsewhere (Dempster and Aitkens 1995;McCrory et al, 1995). Briefly, each subject wore a swimsuit and cap provided by the laboratory whereas body mass was measured to the nearest 100 g by an electronic scale connected to the BOD POD computer.…”
Section: Adp Testingmentioning
confidence: 99%
“…The device is a single egg-shaped unit consisting of two chambers: a test chamber where the subject is seated and a reference chamber with the breathing circuit. As described in detail (Dempster & Aitkens, 1995), the system determines body volume through an air displacement method by the application of Poisson's gas law (McCrory et al, 1995).…”
Section: Air Displacement Plethysmographymentioning