2006
DOI: 10.1155/jammc/2006/20384
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a Multicommuted Flow System for PhotometricEnvironmental Measurements

Abstract: A portable flow analysis instrument is described for in situ photometric measurements. This system is based on light-emitting diodes (LEDs) and a photodiode detector, coupled to a multipumping flow system. The whole equipment presents dimensions of 25  cm × 22  cm × 10  cm, weighs circa 3 kg, and costs 650 €. System performance was evaluated for different chemistries without changing hardware configuration for determinations of (i) Fe3+ with SCN-, (ii) iodometric nitrite determination, (iii) phenol with so… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0
2

Year Published

2008
2008
2016
2016

Publication Types

Select...
5
2
1

Relationship

3
5

Authors

Journals

citations
Cited by 41 publications
(21 citation statements)
references
References 23 publications
(20 reference statements)
0
19
0
2
Order By: Relevance
“…The reduced volume of waste generated (100 L per determination) allows us to conclude that the proposed setup satisfies the Analytical Green Chemistry requirement concerning environmental sustainability [35][36][37].…”
Section: Resultsmentioning
confidence: 82%
“…The reduced volume of waste generated (100 L per determination) allows us to conclude that the proposed setup satisfies the Analytical Green Chemistry requirement concerning environmental sustainability [35][36][37].…”
Section: Resultsmentioning
confidence: 82%
“…This distance can be varied by changing the amount of solid material inserted into the flow cell channel. The control line (d 0 ) was coupled to the digital interface output port 11 in order to allow the LED shining to be controlled by a software.…”
Section: Methodsmentioning
confidence: 99%
“…[6][7][8][9] Its narrow emission band (l = 25 nm) has enabled it to be used without a monochromator system, thus simplifying the photometer design. [10][11][12] Multicommuted flow analysis process affords facilities to design active flow setup constituted by solenoid valves, which have been assembled to work as an independent commutator unit, thus allowing facilities to handle sample and reagent solutions controlled by microcomputer. [8][9][10][11]13,14 Zinc is present in all living cells as a constituent of several molecules involved in proteins, lipids and carbohydrates metabolism, as well as several enzymes.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A procedimento proposto apresentou resposta linear na faixa de 2,5 a 40 µg L -1 (r = -0,995), limite de detecção de 0,3 µg L -1 , desvio relativo menor que 6,5 %, freqüência de amostragem de 25 h Reis et al, (1994). conforme descrito por Ródenas-Torralba, et al, (2006 Bergamin et al, (1978).…”
Section: Dados Internacionais De Catalogação Na Publicação (Cip)unclassified