2017
DOI: 10.1177/1420326x17719954
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a light shelf based on energy consumption for lighting and air conditioning

Abstract: The shading effects of light shelves in indoor thermal environments have not been investigated to date. Thus, this study aims to identify the effectiveness and appropriate parameters required for a light shelf by evaluating its performance in the presence of lighting and air conditioning. A full-scale testbed was established in this study for evaluating the performance of the light shelf. Moreover, the performance evaluation was conducted by calculating the energy consumed for lighting and air conditioning to … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 10 publications
0
12
0
Order By: Relevance
“…As shown in Figure 6, the artificial solar irradiation apparatus enabled us to simulate the sun by controlling the intensity, height, and angle of the artificial light source. This Grade-A apparatus ensured measurement uniformity in accordance with ASTM E927-85 [25], so it was able to obtain valid results between performance evaluations. However, the mechanical characteristics of this apparatus meant that it could only be used to evaluate the performance when the sun was facing south since it was impossible to simulate the solar azimuth.…”
Section: Environmental Setting Of Performance Evaluationmentioning
confidence: 93%
See 2 more Smart Citations
“…As shown in Figure 6, the artificial solar irradiation apparatus enabled us to simulate the sun by controlling the intensity, height, and angle of the artificial light source. This Grade-A apparatus ensured measurement uniformity in accordance with ASTM E927-85 [25], so it was able to obtain valid results between performance evaluations. However, the mechanical characteristics of this apparatus meant that it could only be used to evaluate the performance when the sun was facing south since it was impossible to simulate the solar azimuth.…”
Section: Environmental Setting Of Performance Evaluationmentioning
confidence: 93%
“…As shown in Figure 6, the artificial solar irradiation apparatus enabled us to simulate the sun by controlling the intensity, height, and angle of the artificial light source. This Grade-A apparatus ensured measurement uniformity in accordance with ASTM E927-85 [25], so it…”
Section: Environmental Setting Of Performance Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…• use of a diffusion sheet [26] • evaluation of a light shelf based on energy consumption [27] • light shelf with a solar module [28] • light shelf based on reflector curvature [29] • application of a prism sheet [30] • movable light shelf with a rolling reflector [31] • light shelves with photovoltaic modules [32] Avila-Zamora and Murillo-Quirós experiment • three different anidolic systems were evaluated (anidolic ceiling, integrated anidolic system, anidolic solar blinds)…”
Section: Methods and Eligibility Criteriamentioning
confidence: 99%
“…The use of daylighting systems, in an effort to increase core daylight illuminance, may reduce lighting energy consumption, but careful design is needed in order to avoid possible increases in cooling loads especially in cooling-dominated locations [10]. Thus, the main task of the design teams is to balance antagonistic phenomena, in an effort to maximize the users' thermal and visual comfort.…”
Section: Introductionmentioning
confidence: 99%