1995
DOI: 10.1021/es00009a035
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a High-Purity and High-Stability Continuous Generation System for Nitrous Acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
153
2

Year Published

2000
2000
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 105 publications
(161 citation statements)
references
References 11 publications
6
153
2
Order By: Relevance
“…Gaseous HONO was produced by the reaction of gaseous HCl with solid NaNO 2 in a continuously stirred tank reactor (Figure 3), as suggested by the recent work of Febo et al 19 Consistent with this work, it was found that a temperature of 50°C produced maximum yield. Adjustments were made as needed to keep the reactor in the range of 50 ( 0.5°C.…”
Section: Experimental Approach and Data Reductionsupporting
confidence: 76%
“…Gaseous HONO was produced by the reaction of gaseous HCl with solid NaNO 2 in a continuously stirred tank reactor (Figure 3), as suggested by the recent work of Febo et al 19 Consistent with this work, it was found that a temperature of 50°C produced maximum yield. Adjustments were made as needed to keep the reactor in the range of 50 ( 0.5°C.…”
Section: Experimental Approach and Data Reductionsupporting
confidence: 76%
“…24 However, the desired concentration of HONO was produced by the reaction of NaNO2 with water vapor 26 in this study. Specifically, humidified zero air was introduced into a glass chamber (7.5-cm inner diameter and 24-cm length).…”
Section: Preparation Of Gaseous Hono and No2mentioning
confidence: 87%
“…In this study, simultaneous measurements of HONO using IBBCEAS and a chemiluminescence NOx analyzer with a molybdenum reducing catalyst (Mo converter) was carried out. Because the NOx analyzer with a Mo converter can measure HONO concentrations in the absence of any other nitrogen compounds, 14,24 comparisons between these two different measurement techniques can be used to validate measurements of HONO using IBBCEAS. Because NO2 and HONO coexist in ambient air, the simultaneous measurement of the mixtures of HONO and NO2 gases was undertaken.…”
Section: Introductionmentioning
confidence: 99%
“…The inlet was overflowed with this gas combination for more than 8 h. NH 3(g) and HONO (g) were produced from a permeation device housed in a temperature-controlled oven [e.g., Markovic et al, 2012], with HONO (g) being generated at 50% relative humidity in a NaNO 2(s) -packed tubing fed with HCl (g) from a permeation device according to the method of Febo et al [1995]. A maximum breakthrough of 4% of gas phase HONO (g) to the particle channel was observed at the highest examined HONO (g) mixing ratio of 2 ppbv, which is above the maximum HONO (g) observed in this study.…”
Section: Aim-ic Hono Collection Efficiencymentioning
confidence: 99%