2001
DOI: 10.1016/s0168-9002(00)00669-0
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
62
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 115 publications
(62 citation statements)
references
References 8 publications
0
62
0
Order By: Relevance
“…Given the 3-D position information provided by the detector, we can identify events from a specific interaction location and with 511 keV full energy deposition. The mean waveform for these events were obtained by averaging over measured waveforms lined up at the same starting time: (2) where T i is the true interaction timing obtained from the BaF 2 coincidence detector. w5 11 keV (t) is the mean waveform resulting from an 511 keV energy deposited at this given location, assuming that the interaction occurred at t = 0.…”
Section: Using Cathode Waveform For Timing Estimationmentioning
confidence: 99%
See 2 more Smart Citations
“…Given the 3-D position information provided by the detector, we can identify events from a specific interaction location and with 511 keV full energy deposition. The mean waveform for these events were obtained by averaging over measured waveforms lined up at the same starting time: (2) where T i is the true interaction timing obtained from the BaF 2 coincidence detector. w5 11 keV (t) is the mean waveform resulting from an 511 keV energy deposited at this given location, assuming that the interaction occurred at t = 0.…”
Section: Using Cathode Waveform For Timing Estimationmentioning
confidence: 99%
“…This unique capability is detailed in Refs. [1,2]. Based on this information, we select an appropriate mean waveform and then use the fitting process to find interaction timing.…”
Section: Using Cathode Waveform For Timing Estimationmentioning
confidence: 99%
See 1 more Smart Citation
“…Employing semiconductor imaging spectrometers, with their good resolutions, is hence a promising approach to realize high sensitivity Compton telescopes. From this point of view, Compton telescopes based on Si, Ge ,CZT and CdTe are proposed and development is on-going by many groups [1][2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…An alternative way to image gamma rays without the use of a collimator is Compton imaging [12][13][14][15][16][17][18][19][20][21][22]. This imaging concept relies on the Compton effect and therefore converts the otherwise limiting process of multiple interaction in the detector into a required process.…”
Section: Overview Of Gamma-ray Imaging Conceptsmentioning
confidence: 99%