2015
DOI: 10.1016/j.nucmedbio.2015.06.012
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of [11C]methyl-losartan and [11C]methyl-EXP3174 for PET imaging of renal AT1receptor in rats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(16 citation statements)
references
References 38 publications
1
15
0
Order By: Relevance
“…18,19 In order to improve the RCY of the reaction, both methylating agents were tested, [ C]7 t R = 3.7 min), UV in black (λ = 254 nm, t R = 3.8 minutes) and the nonradioactive standard 7 in red (UV, λ = 254 nm, t R = 3.8 min). 11 C-Methylation was carried out in the presence of Kryptofix 222 and potassium carbonate.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…18,19 In order to improve the RCY of the reaction, both methylating agents were tested, [ C]7 t R = 3.7 min), UV in black (λ = 254 nm, t R = 3.8 minutes) and the nonradioactive standard 7 in red (UV, λ = 254 nm, t R = 3.8 min). 11 C-Methylation was carried out in the presence of Kryptofix 222 and potassium carbonate.…”
Section: Resultsmentioning
confidence: 99%
“…Utilization of this cryptant was previously reported to enhance the reactivity of the base increasing the formation of the carboxylate ion for methylation. 18,19 In order to improve the RCY of the reaction, both methylating agents were tested, [ 11 . The difference in the retention times between radiation and UV detection is due to detectors being in series deprotection reaction times resulted in lower RCY, various concentrations of HCl were tested for the deprotection reaction, while minimizing the potential degradation of the 11 C-methyl ester derivative.…”
Section: Resultsmentioning
confidence: 99%
“…Although a few PET AT 1 R radioligands have been evaluated for cardiovascular [39,40], renal [22][23][24][41][42][43][44] and brain [18,45] AT 1 R imaging, most of them were labeled with 11 C, which brings some disadvantages over 18 F in the clinical practice, such as the presence of an in-site cyclotron. Recently, it was reported the synthesis of [ 18 F]FPyKYNE-losartan (Figure 1), a losartan-derivative containing a hydrophobic motif that could favor a non-specific liver uptake [21].…”
Section: Discussionmentioning
confidence: 99%
“…PET imaging uses radiopharmaceuticals labelled with positron-emitting radioisotopes such as carbon-11 ( 11 C) and fluorine-18 ( 18 F). Several AT 1 R radioligands have been designed, synthesized and evaluated for molecular imaging of AT 1 receptors [15][16][17][18][19][20][21][22][23][24]. Most of these AT 1 R radioligands (Figure 1), mostly derivatives from commercial angiotensin receptor blockers (ARBs), were labeled with 11 C which is a drawback in the clinic practice due to the very short half-life of 20.4 min [25].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation