2014 49th International Universities Power Engineering Conference (UPEC) 2014
DOI: 10.1109/upec.2014.6934827
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation method for harmonic distortion and power losses of photovoltaic systems using LabVIEW software

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(19 citation statements)
references
References 5 publications
0
19
0
Order By: Relevance
“…With relation to harmonic distortion indicators, the prevalent indicator to measure the harmonic distortion is the representation of the “ harmonic spectrum ,” since it is used in 67% of the existing studies . With a similar level of penetration, the THD is used by 71% of the works , and the display of the “ voltage and current waveforms ” is included in 52% of the studies .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…With relation to harmonic distortion indicators, the prevalent indicator to measure the harmonic distortion is the representation of the “ harmonic spectrum ,” since it is used in 67% of the existing studies . With a similar level of penetration, the THD is used by 71% of the works , and the display of the “ voltage and current waveforms ” is included in 52% of the studies .…”
Section: Resultsmentioning
confidence: 99%
“…The non‐linear loads most commonly used are power converters such as rectifiers, inverters, etc. . Additionally, several authors have opted to select a widely applied software and perform customized modeling and simulation exercises .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…With relation to harmonic distortion indicators, the prevalent indicator to measure the harmonic distortion is the representation of the “harmonic spectrum,” since it is used in 68% of the existing studies . With a similar level of penetration, the THD is used by 63% of the works , and the display of the “voltage and current waveforms” is included in 47% of the studies .…”
Section: Resultsmentioning
confidence: 99%
“…With a similar level of penetration, the THD is used by 63% of the works , and the display of the “voltage and current waveforms” is included in 47% of the studies . The real PF is another metric commonly used in harmonic modeling and simulation, considered in 32% of the existing studies . With a lower level of penetration, the use of the root‐mean‐square values of the current and voltage signals are considered by 16% of the works , which is a similar percentage as for the P average metric .…”
Section: Resultsmentioning
confidence: 99%