Evaluation and validation of an accurate mass screening method for the analysis of pesticides in fruits and vegetables using liquid chromatography–quadrupole-time of flight–mass spectrometry with automated detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
23
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 72 publications
(26 citation statements)
references
References 9 publications
1
23
0
Order By: Relevance
“…18,19 Although many applications have been successfully implemented, the identification process represents the major obstacle to having fully automated high-throughput screening methods. 20 This problem is particularly magnified when target compounds at low concentrations are nested in complex samples where matrix compounds are frequently present in higher amounts, producing spectra that are difficult to interpret or exacerbate the detection by hampering the ionization process. These challenges are frequently met in most published methods when analysts have to develop analytical strategies to detect ultra-trace levels of small molecules in complex biological samples.…”
Section: Introductionmentioning
confidence: 99%
“…18,19 Although many applications have been successfully implemented, the identification process represents the major obstacle to having fully automated high-throughput screening methods. 20 This problem is particularly magnified when target compounds at low concentrations are nested in complex samples where matrix compounds are frequently present in higher amounts, producing spectra that are difficult to interpret or exacerbate the detection by hampering the ionization process. These challenges are frequently met in most published methods when analysts have to develop analytical strategies to detect ultra-trace levels of small molecules in complex biological samples.…”
Section: Introductionmentioning
confidence: 99%
“…Hybrid analyzers such as Q‐TOF‐MS allow a simultaneous recording of precursor and fragment ions in all‐ion fragmentation methods, for example, using MS collision energy elevated experiment (MS E ) technology (Waters, Milford, MA, USA) in parallel low collision energy conditions (e.g., 6 eV) for precursor ion acquisition and higher collision energy conditions (a ramp of elevated collision energy of 10–45 eV) for fragment ion acquisition . Nevertheless, these all‐ion‐fragmentation approaches result in highly convoluted MS E spectra, in particular caused by coeluting matrix substances .…”
Section: Introductionmentioning
confidence: 99%
“…After data acquisition, the raw data was imported into the TCM database. Then, automated detection and data filtering were performed by the UNIFI and the peaks detected were evaluated against a compound library of TCMs, in which chemical structure, molecular formula, molecular weight, English name and Chinese name in exact mass of several thousand unique compounds are involved (López et al, ). Finally, the identified structures were confirmed automatically by mass fragments.…”
Section: Resultsmentioning