2018
DOI: 10.1016/j.enconman.2018.06.070
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation and improvement of the thermal performance of different types of horizontal ground heat exchangers based on techno-economic analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
40
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 66 publications
(40 citation statements)
references
References 46 publications
0
40
0
Order By: Relevance
“…Because the motor is assumed to be kept outside of the fluid stream, so the waste heat of the motor impacts the ambient, and f motorloss would have a value of 0. Heat losses of the piping can be calculated by integrating the following equation [10,26,27].…”
Section: Piping Heat Losses and Pump Power Calculationmentioning
confidence: 99%
See 2 more Smart Citations
“…Because the motor is assumed to be kept outside of the fluid stream, so the waste heat of the motor impacts the ambient, and f motorloss would have a value of 0. Heat losses of the piping can be calculated by integrating the following equation [10,26,27].…”
Section: Piping Heat Losses and Pump Power Calculationmentioning
confidence: 99%
“…Properties of the water flow at the set point temperature is determined from Holman [29] as are presented in Table 3. According to the pipe shape in cylindrical coordinates, the resistance values of the pipe, insulation, and backfill are obtained from the following equation [27,30].…”
Section: Piping Heat Losses and Pump Power Calculationmentioning
confidence: 99%
See 1 more Smart Citation
“…Wang et al [8] examined tube heat transfer properties at diverse impact angle conditions, and three kinds of heat exchangers with different structures were selected for investigating heat transfer and fluid flow characteristics under different impact angles and different pipe inclinations. Habibi et al [9] established a numerical mode according to 3D fluid dynamics simulation using computational fluid dynamics. Thereafter, the as-constructed model was applied in evaluating the cost of initial installation and heating performance of the horizontal buried pipe.…”
Section: Introductionmentioning
confidence: 99%
“…They proposed an elaborate economical work for stand-alone and hybrid earth to air tunnel system design was proposed to be outright for each layout and climatology type. Mohammad Habibi and Ali Hakkaki-Fard [25], presented a numerical simulation based on 3D model of horizontal Ground Heat Exchangers with CFD methods was developed by the authors. This simulation for evaluating the thermal efficiency and the first installation price of the horizontal GHEs.…”
Section: Introductionmentioning
confidence: 99%