Evaluation and correction of aberrations in an optical correlator by phase-shifting interferometry

Abstract: We propose a new method for evaluating and correcting aberrations in a Vander Lugt correlator. The technique is achieved with liquid-crystal displays of the correlator and allows the task to be performed in situ. We present the theory on which the method is based and the experimental results that we obtained by applying it in a convergent correlator.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 7 publications
0
7
0
Order By: Relevance
“…Zoom system has been widely applied to a variety important areas, such as medical and health, information technology, research education and national defense construction [1][2][3][4][5][6]. The conventional design is to use multiple solid lenses with fixed focal lengths.…”
Section: Introductionmentioning
confidence: 99%
“…Zoom system has been widely applied to a variety important areas, such as medical and health, information technology, research education and national defense construction [1][2][3][4][5][6]. The conventional design is to use multiple solid lenses with fixed focal lengths.…”
Section: Introductionmentioning
confidence: 99%
“…Widespread application has been found for optical zoom systems in optical instruments and systems, including target detection, video surveillance, electronic equipment, and tracking [1][2][3][4][5][6]. In order to adjust the magnification of the zoom system, the most common design is to regulate the position between the components of the multiple optical elements mechanically.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, the introduction of liquid crystals permits the implementation of the interferometric methods by phase shifting [4]. In previous works [5,6] we proposed a PDI that uses liquid crystal displays. In the first case [5], the PDI was used to measure in situ aberrations in an optical correlator.…”
Section: Introductionmentioning
confidence: 99%
“…In previous works [5,6] we proposed a PDI that uses liquid crystal displays. In the first case [5], the PDI was used to measure in situ aberrations in an optical correlator. While in the second [6], the interferometer was used in digital holography applications.…”